In this study, the operation of a ground source heat pump system was investigated over a 25-year period with careful attention paid to the effects of groundwater flow and intermittent operation strategies. First, geological and hydrogeological investigations were conducted, after which ground thermal properties were determined by thermal response tests. In order to predict the heat transfer within borehole heat exchangers under a specific operating system, a numerical model was developed using finite element subsurface flow & transport simulation system (FEFLOW). The numerical model was validated with thermal response test measurements. Three operation conditions including continuous system operation without groundwater flow, continuous system operation with groundwater flow, and intermittent operation with groundwater flow were examined. Results indicate that ground temperature disturbance was effectively reduced during groundwater flow and the intermittent operation of the system. Compared with continuous system operation without groundwater flow, the borehole heat exchanger heat transfer rate increases by 10% with groundwater flow conditions and increases by 16% with further implementation of the intermittent operation strategy. Intermittent operation with groundwater flow is highly recommended for the sustainable operation of ground source heat pump system.
机译:在这项研究中,对地源热泵系统的运行进行了25年的调查,并特别注意了地下水流量和间歇运行策略的影响。首先,进行了地质和水文地质调查,然后通过热响应测试确定了地热特性。为了预测特定操作系统下钻孔换热器内的热传递,使用有限元地下流动和传输模拟系统(FEFLOW)建立了数值模型。数值模型通过热响应测试测量得到验证。研究了三种运行条件,包括无地下水的连续系统运行,有地下水的连续系统运行和有地下水的间歇运行。结果表明,在地下水流动和系统间歇运行期间,有效降低了地面温度扰动。与没有地下水流的连续系统运行相比,井眼热交换器的传热率在地下水流条件下增加了10%,在进一步实施间歇运行策略的情况下增加了16%。对于地源热泵系统的可持续运行,强烈建议间歇运行地下水。

著录项

  • 来源
    《Energy Exploration & Exploitation》 |2019年第2期|677-690|共14页
  • 作者单位

    Chinese Acad Geol Sci, Inst Hydrogeol & Environm Geol, 268 Zhonghuabei St, Shijiazhuang 050061, Hebei, Peoples R China|China Univ Geosci, Sch Environm Studies, Wuhan, Hubei, Peoples R China;

    China Univ Geosci, Fac Engn, Wuhan, Hubei, Peoples R China;

    Chinese Acad Geol Sci, Inst Hydrogeol & Environm Geol, 268 Zhonghuabei St, Shijiazhuang 050061, Hebei, Peoples R China;

    Chinese Acad Geol Sci, Inst Hydrogeol & Environm Geol, 268 Zhonghuabei St, Shijiazhuang 050061, Hebei, Peoples R China;

    ShanDong Geomineral Engn Grp Co Ltd, Jinan, Shandong, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ground source heat pump system; borehole heat exchanger; thermal response test; groundwater flow; intermittent operation strategy;