This paper presents experimental results of air conditioning system are provided for a 13 meter-long bus; and it was explained that how the instantaneous cooling capacity can be determined with the results are obtained. Instantaneous cooling capacity determined by the experimental results is compared with the heat gain of the bus which is calculated using the radiant time series method. So, the experimental results and analytical results were shown compatible with each other. Compatibility of the instantaneous cooling capacity values of experimental results with the data provided by manufacturers can be determined quickly with the method described in this study.
机译:本文介绍了为13米长的公交车提供空调系统的实验结果;并解释了如何根据结果确定瞬时冷却能力。将实验结果确定的瞬时制冷量与使用辐射时间序列方法计算得出的公交车的热增益进行比较。因此,实验结果和分析结果相互兼容。实验结果的瞬时冷却能力值与制造商提供的数据的兼容性可以通过本研究中描述的方法快速确定。