首页> 外文期刊>IEEE Transactions on Energy Conversion >Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction Generators
【24h】

Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction Generators

机译:独立双馈感应发电机不平衡运行的控制系统

获取原文
获取原文并翻译 | 示例
           

摘要

In this letter, a novel control system for the operation of a doubly fed induction generator (DFIG), feeding an unbalanced three-phase load is presented. The load unbalance is compensated using the front-end converter. The control system is based on two revolving axes, rotating at plusmnomegae, which are used to control the positive and negative sequence currents supplied by the front-end converter. Experimental results obtained from a 2-kW experimental prototype are presented and discussed in this letter.
机译:在这封信中,提出了一种新颖的控制系统,用于控制双馈感应发电机(DFIG)的运行,该发电机为三相不平衡负载供电。使用前端转换器可以补偿负载不平衡。该控制系统基于两个以正负号旋转的旋转轴,用于控制前端转换器提供的正序和负序电流。本文介绍并讨论了从2kW实验原型获得的实验结果。