Thermal cycling of generators, occurring during intermittent operation of power stations, increases the thermomechanical stress on the stator groundwall insulation and can, therefore, contribute to failure of the generator. Thermal cycling stresses can, to some extent, be replicated and accelerated in laboratory tests. Such tests are performed to ascertain whether a new stator winding insulation system can handle intermittent operation, to evaluate the relative difference between different types of insulations or to investigate degradation processes and failure mechanisms. Results from thermal cycling tests of hydrogenerator stator windings are reviewed. Only stator windings of air-cooled hydrogenerators with thermoset groundwall insulation of mica-epoxy or mica-polyester are considered. The published literature of laboratory experiments performed in order to study effects of thermal cycling on groundwall insulation through different types of diagnostic measurements is described and discussed. Partial discharge (PD) and tanδ measurements gave, in some cases, an indication of a trend in the condition during thermal cycling, while in other cases it was difficult to interpret the test results. Many agree that measurement of breakdown voltage of stator windings can give an indication of the aging and remaining lifetime of the insulation. The ability of other measurements such as tan δ, PD, and voltage endurance to assess the remaining lifetime of the stator winding is less convincing since the results vary greatly.
机译:在发电站间歇运行期间发生的发电机热循环会增加定子接地壁绝缘层上的热机械应力,因此可能导致发电机故障。热循环应力在某种程度上可以在实验室测试中复制和加速。进行此类测试以确定新的定子绕组绝缘系统是否可以处理间歇运行,评估不同类型绝缘之间的相对差异或调查退化过程和故障机理。审查了水轮发电机定子绕组的热循环测试结果。仅考虑具有云母环氧树脂或云母聚酯热固性接地绝缘的风冷水轮发电机的定子绕组。描述和讨论了通过各种类型的诊断测量来研究热循环对地下墙保温的影响的实验室实验的公开文献。在某些情况下,局部放电(PD)和tanδ的测量值表明了热循环过程中状态的趋势,而在其他情况下,则难以解释测试结果。许多人同意,测量定子绕组的击穿电压可以指示绝缘的老化和剩余寿命。由于结果变化很大,其他测量值(例如tanδ,PD和耐压性)评估定子绕组剩余寿命的能力令人信服。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号