首页> 外文期刊>IEEE Transactions on Energy Conversion >Influence of Insulation Thermal Aging on the Temperature Assessment in Electrical Machines
【24h】

Influence of Insulation Thermal Aging on the Temperature Assessment in Electrical Machines

机译:绝缘热老化对电机温度评估的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Thermal modeling and temperature assessment of electrical machines often rely on the use of lumped-parameter thermal networks. A historic limitation of analytical thermal models is their need for an experimental fine-tuning, necessary for selecting the appropriate values of thermal conductivity and convection heat transfer coefficients. This evaluation procedure is commonly carried out at the design stage of a new machine, by assuming that its thermal behavior will remain unchanged throughout its whole lifetime. This paper demonstrates, through an in-depth experimental investigation, how the capability of heat extraction from a machine's hot spot towards the coolant can be strongly affected by the level of thermal aging of its insulation system. Based on the experimental findings, a decrement of the winding equivalent thermal conductivity is noted as the thermal aging accumulates, with a corresponding progressive increment in hot-spot temperature.
机译:电机的热建模和温度评估通常依赖于使用集合参数热网络。分析热模型的历史局限性是他们需要实验微调,用于选择相应的导热性和对流传热系数的适当值。该评估程序通常在新机器的设计阶段进行,假设其热行为在整个寿命期间保持不变。本文通过深入的实验研究表明,如何从机器的热点向冷却剂中提取的热量提取能力如何受到绝缘系统的热老化水平的强烈影响。基于实验结果,将绕组等效导热率的减少指出,作为热老化积累,在热点温度下具有相应的逐渐增加。