The impact of natural ventilation of a roof cavity on improvement of the thermal environment and reduction of cooling load of a factory building is discussed. A computer program was developed with the logic in a companion paper [1] to observe the effect of cavity ventilation on the operative temperature of the occupied zone in the factory. Comparisons were made between factories with a cavity roof and a single roof in the Japanese climate. Results showed that the cavity roof was superior to the single roof in lowering the operative temperature by about 4.4 ℃ When the factory was air conditioned, the cooling load reduction reached approximately 50% during the summer to maintain an operative temperature of 26 ℃. Results showed that a naturally ventilated cavity roof has excellent potential for improving the indoor thermal environment and energy savings of factory buildings without complicated cooling installations and life time power consumption.
机译:讨论了屋顶空腔的自然通风对改善热环境和降低工厂建筑物的冷却负荷的影响。用附带的逻辑[1]开发了一个计算机程序,以观察腔通风对工厂所占区域工作温度的影响。在日本气候下,对带有空心屋顶和单个屋顶的工厂进行了比较。结果表明,空腔屋顶在将工作温度降低约4.4℃方面优于单屋顶。当工厂装有空调时,夏季的冷却负荷降低约50%,以保持工作温度为26℃。结果表明,自然通风的空腔屋顶具有改善室内热环境和工厂建筑物节能的极佳潜力,而无需复杂的冷却装置和使用寿命内的功耗。

著录项

  • 来源
    《Energy and Buildings》 |2011年第1期|p.211-218|共8页
  • 作者

    L.Susanti; H.Homma; H.Matsumoto;

  • 作者单位

    Department of Industrial Engineering. Andalas University, Padang, Indonesia;

    Department of Architecture and Civil Engineering, Toyohashi University of Technology, Toyohashi, Japan;

    Department of Architecture and Civil Engineering, Toyohashi University of Technology, Toyohashi, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cavity roof; natural ventilation; operative temperature; cooling load; energy saving;

    机译:空腔屋顶自然通风;工作温度冷却负荷节约能源;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号