In this paper, the refrigerant HFC-161 as an alternative refrigerant to HFC-410A is presented in a small scale refrigeration system. Theoretical cycle performances of HFC-410A, HFC-32 and HFC-161 are calculated and analyzed under the rated working condition. The results show that the COP of HFC-161 is 10.0% and 17.8% higher than that of HFC-32 and HFC-410A, respectively, and the discharge temperature of HFC-161 is the lowest among these refrigerants. Experimental tests were also performed on a vapor-compression refrigeration system with a rotor compressor which was originally designed for HFC-410A to compare the cycle performance of the HFC-410A, HFC-32 and HFC-161 under different working conditions. Experimental results show that the HFC-161 can achieve higher COP by 15-25% than HFC-410A and HFC-32, and the discharging temperature of HFC-161 is much lower than that of HFC-410A and HFC-32. The power consumption and cooling capacity of HFC-161 are the smallest among these refrigerants. The cooling capacity and COP of HFC-32 is very similar to those of HFC-410A, but discharging temperature and power consumption of HFC-32 are slightly higher those of HFC-410A under most working conditions. These results show that HFC-161 is a promising alternative refrigerant to HFC-41 OA for small-scale refrigeration systems, which supply a very valuable reference for the actual system of HFC-161.
机译:本文在小型制冷系统中介绍了作为HFC-410A替代制冷剂的制冷剂HFC-161。在额定工作条件下,对HFC-410A,HFC-32和HFC-161的理论循环性能进行了计算和分析。结果表明,HFC-161的COP分别比HFC-32和HFC-410A高10.0%和17.8%,并且HFC-161的排放温度在这些制冷剂中最低。还对带有转子压缩机的蒸汽压缩制冷系统进行了实验测试,该系统最初是为HFC-410A设计的,用于比较HFC-410A,HFC-32和HFC-161在不同工作条件下的循环性能。实验结果表明,HFC-161的COP值比HFC-410A和HFC-32高15-25%,HFC-161的放电温度远低于HFC-410A和HFC-32。在这些制冷剂中,HFC-161的功耗和冷却能力最小。 HFC-32的冷却能力和COP非常类似于HFC-410A,但是在大多数工作条件下,HFC-32的放电温度和功耗略高于HFC-410A。这些结果表明,对于小规模制冷系统,HFC-161是一种有希望的替代HFC-41 OA的制冷剂,它为HFC-161的实际系统提供了非常有价值的参考。

著录项

  • 来源
    《Energy and Buildings》 |2012年第1期|p.33-38|共6页
  • 作者单位

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cycle performance; HFC-161; HFC-410A; HFC-32;

    机译:循环性能;HFC-161;HFC-410A;HFC-32;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号