A study was conducted to determine the in situ thermal transmittance and thermal resistance of two exterior reinforced precast concrete walls of a building constructed with hollow panels. The results indicate that the North and East facing walls have a mean thermal transmittance (air to air) of 1.459 and 1.803 W/m~2 K, respectively. The mean thermal resistance value (surface to surface) of the North and East walls is 0.355 and 0.352 m~2 K/W, respectively. While the thermal transmittance depends on the wall orientation and the outside weather conditions, the thermal resistance is independent of the wall orientation. The results also indicate that a monitoring period of six days is sufficient to ascertain the in situ thermal transmittance and thermal resistance of reinforced precast concrete walls.
机译:进行了一项研究,以确定由空心板建造的建筑物的两个外部钢筋混凝土预制墙的原位传热率和热阻。结果表明,朝北和朝东的墙的平均热透射率(空气对空气)分别为1.459和1.803 W / m〜2K。北壁和东壁的平均热阻值(表面到表面)分别为0.355和0.352 m〜2 K / W。虽然热传递率取决于墙的朝向和外部天气条件,但热阻与墙的朝向无关。结果还表明,为期六天的监视时间足以确定钢筋混凝土预制墙的现场传热和热阻。