Most historic churches are characterised by low thermal efficiency due primarily to their architectural design and the traditional materials used in their construction. Heating the huge volumes of air involved may be more or less effective depending on the HVAC system used. Up until very recently, traditional heating has been the system of choice in Spanish churches. The present study analysed the parish church at Talamanca de Jarama (a village on the outskirts of Madrid), where the forced hot-air system was found to induce wide fluctuations in indoor thermal-hygrometric (T/RH) conditions, in turn translating into the temporal and horizontal stratification of temperature and relative humidity. As a result, the thermal comfort sought for parishioners is not reached, for the air remains cold at pew height while heat accumulates in the upper area of the church. A three-dimensional sensor network was designed to monitor these conditions. Suspended from helium balloons, the sensors could record the indoor air temperature and humidity without causing any damage whatsoever to church property.
机译:大多数历史悠久的教堂的特点是热效率低,这主要归因于其建筑设计和建筑中使用的传统材料。取决于所使用的HVAC系统,加热涉及的大量空气可能或多或少有效。直到最近,传统供暖还是西班牙教堂中的首选系统。本研究分析了Talamanca de Jarama(马德里郊区的一个村庄)的教区教堂,该教堂的强制热风系统导致室内温湿度(T / RH)条件产生较大波动,进而转化为温度和相对湿度的时间和水平分层。结果,达不到教区居民所要求的热舒适性,因为空气在座位高度处保持冷态,而热量则积聚在教堂的上部。设计了三维传感器网络来监视这些情况。这些传感器悬挂在氦气球上,可以记录室内空气的温度和湿度,而不会对教堂财产造成任何损害。

著录项

  • 来源
    《Energy and Buildings》 |2014年第6期|119-132|共14页
  • 作者单位

    Instituto de Geociencias IGEO (CSIC, UCM), C/Jose Antonio Novais 12,28040 Madrid, Spain,Departamento de Petrologia y Geoquimica, Facultad Ciencias Geologicas, Universidad Complutense de Madrid, C/Jose Antonio Novdis 12, 28040 Madrid, Spain;

    Instituto de Geociencias IGEO (CSIC, UCM), C/Jose Antonio Novais 12,28040 Madrid, Spain,CEI - Campus Moncloa (UCM-UPM, CSIC), Madrid, Spain;

    Instituto de Geociencias IGEO (CSIC, UCM), C/Jose Antonio Novais 12,28040 Madrid, Spain,CEI - Campus Moncloa (UCM-UPM, CSIC), Madrid, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Heating church; Traditional heating systems; Thermal-hygrometric efficiency; Monitoring strategy;

    机译:暖气教堂;传统供暖系统;热湿效率;监控策略;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号