The mudéjar church of Santa María (Ateca) is valuable for its architecture and the altarpiece contained inside. Ateca is a village with continental climate characterized by cold winters and hot summers. In this paper we are interested in analysing the effect of temperature and relative humidity (RH) changes produced by the heating system on the altarpiece. Therefore, a monitoring system of 15 temperature and 15 relative humidity sensors was installed with a recording frequency of a data point per minute. The main contribution of this paper is the quantitative study of the effect of the heating system on the thermo-hygrometric parameters using statistical techniques such as ANOVA, mean daily trajectories or bivariate plots, and the proposal of an innovative dynamic contour plot. As results, the heating system produces a substantial increase (decrease) of temperature (RH) causing an hourly variation of these physical parameters detrimental to the conservation of the altarpiece, especially in its higher areas.
机译:圣玛丽亚(Ateca)的Mudjar教堂因其建筑风格和内部的祭坛而有价值。阿特卡(Ateca)是一个拥有大陆性气候的村庄,其特征是冬季寒冷和夏季炎热。在本文中,我们有兴趣分析加热系统在祭坛上产生的温度和相对湿度(RH)变化的影响。因此,安装了一个由15个温度和15个相对湿度传感器组成的监视系统,其记录频率为每分钟数据点。本文的主要贡献是使用ANOVA,平均日轨迹或二元图等统计技术对加热系统对温湿度参数的影响进行定量研究,并提出了创新的动态轮廓图。结果,加热系统产生了温度(RH)的大幅增加(降低),导致这些物理参数的每小时变化,不利于祭坛的保存,特别是在祭坛的较高区域。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号