首页> 外文期刊>Energy and Buildings >Thermal performance evaluation of fiber-reinforced polymer thermal breaks for balcony connections
【24h】

Thermal performance evaluation of fiber-reinforced polymer thermal breaks for balcony connections

机译:阳台连接用纤维增强聚合物热断裂的热性能评估

获取原文
获取原文并翻译 | 示例

摘要

The potential effects of high-performance fiber-reinforced polymer thermal breaks for balcony connections on the thermal losses and heating needs of a typical residential building in Switzerland were investigated. In an optimized form, these new thermal breaks have a linear thermal transmittance of ψ ≤ 0.10 W/mK. The reduction of the total transmission losses via these optimized thermal breaks through the building envelope remained modest. If however losses through the thermal bridges are related to those through the opaque envelope elements only, the latter were reduced by up to 18% for an optimum envelope. If furthermore these losses are related to the heating needs of a building with an optimum envelope, their magnitude is reduced by 41% if ψ is decreased from 0.30 (recommended value from SIA) to 0.10W/mK. In attempting to approach the goal of zero-energy buildings with zero heating needs, the thermal losses through thermal breaks can thus have a significant effect.
机译:研究了用于阳台连接的高性能纤维增强聚合物热断裂对瑞士典型住宅建筑的热损失和供热需求的潜在影响。这些新的热断点以优化的形式具有ψ≤0.10 W / mK的线性热透射率。通过这些优化的穿过建筑物围护结构的热中断来减少总的传输损耗仍然是适度的。但是,如果通过热桥的损耗仅与通过不透明的包络线元素造成的损失有关,则为获得最佳包络线,不透明的包络线元素最多可减少18%。此外,如果这些损耗与具有最佳围护结构的建筑物的供暖需求有关,则当ψ从0.30(SIA的推荐值)降至0.10W / mK时,其幅度将降低41%。在尝试实现零能耗需求的零能耗建筑的目标时,通过热中断产生的热损失可能会产生重大影响。

著录项

  • 来源
    《Energy and Buildings 》 |2014年第2期| 365-371| 共7页
  • 作者单位

    Composite Construction Laboratory CCLab, Ecole Polytechnique Federale de Lausanne, EPFL Station 16, CH-1015 Lausanne, Switzerland;

    Composite Construction Laboratory CCLab, Ecole Polytechnique Federale de Lausanne, EPFL Station 16, CH-1015 Lausanne, Switzerland;

    Composite Construction Laboratory CCLab, Ecole Polytechnique Federale de Lausanne, EPFL Station 16, CH-1015 Lausanne, Switzerland;

    Composite Construction Laboratory CCLab, Ecole Polytechnique Federale de Lausanne, EPFL Station 16, CH-1015 Lausanne, Switzerland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Thermal bridges; Linear thermal transmittance; Balcony connections; Fiber-reinforced polymers;

    机译:热桥;线性导热率;阳台连接;纤维增强聚合物;