首页> 外文期刊>Energy and Buildings >Energy and exergy analysis of a ground source heat pump system for a public building in Wuhan, China under different control strategies
【24h】

Energy and exergy analysis of a ground source heat pump system for a public building in Wuhan, China under different control strategies

机译:不同控制策略下武汉市某公共建筑地源热泵系统的能量和火用分析

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents the energy and exergy studies of a ground source heat pump (GSHP) system for a public building in Wuhan, China under five different control strategies to improve the system performance. Original system was under manual operation with constant frequency heat pump, constant speed circulation pumps, and constant water flow rate. The five control strategies were: 1) Automatic ON/OFF control based on Building Load Ratio (BLR); 2) Optimum circulation flow rate control; 3) Optimum ON/OFF control with variable speed heat pump units; 4) Variable flow control by adjusting valve position; 5) Variable flow control by variable speed pumps. The results of the system exergy efficiency, exergy loss, COP, and energy consumption under different operation scenarios are presented. By comparing original operation with the best case (scenario five), it is found that during cooling and heating season, the system exergy efficiency was improved from 9.0% to 10.4% and from 6.1% to 6.9%; exergy loss dropped by 31% and 51%; COP increased from 3.2 to 3.7 and from 2.7 to 3.8; and energy consumption was reduced by 37% and 60%, respectively. (C) 2017 Elsevier B.V. All rights reserved.
机译:本文介绍了在五种不同的控制策略下,针对武汉某公共建筑的地源热泵(GSHP)系统的能量和火用研究,以提高系统性能。原始系统是在手动操作下使用恒定频率的热泵,恒定速度的循环泵和恒定的水流量。这五种控制策略是:1)基于建筑物负荷率(BLR)的自动ON / OFF控制; 2)最佳循环流量控制; 3)变速热泵机组的最佳开/关控制; 4)通过调节阀位进行可变流量控制; 5)通过变速泵进行可变流量控制。给出了系统在不同运行场景下的系统能效,能值损失,COP和能耗的结果。通过将原始操作与最佳情况(方案五)进行比较,发现在制冷和制热季节,系统的系统火用效率从9.0%提高到10.4%,从6.1%提高到6.9%。火用损失分别下降了31%和51%; COP从3.2增加到3.7,从2.7增加到3.8;能源消耗分别减少了37%和60%。 (C)2017 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2017年第10期|301-312|共12页
  • 作者单位

    Huazhong Univ Sci & Technol, Sch Environm Sci & Engn, Wuhan 430074, Hubei, Peoples R China;

    Huazhong Univ Sci & Technol, Sch Environm Sci & Engn, Wuhan 430074, Hubei, Peoples R China;

    Wuhan Univ Technol, Sch Civil Engn & Architecture, Wuhan 430070, Hubei, Peoples R China;

    Victoria Univ, Coll Engn & Sci, Melbourne, Vic 8001, Australia;

    Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Hubei, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Exergy analysis; Energy analysis; Ground source heat pump; Control strategies; Optimization;

    机译:火用分析能量分析地源热泵控制策略优化;