首页> 外文期刊>Energy and Buildings >Evaluation of thermal comfort in an office building served by a liquid desiccant-assisted evaporative cooling air-conditioning system
【24h】

Evaluation of thermal comfort in an office building served by a liquid desiccant-assisted evaporative cooling air-conditioning system

机译:液体干燥剂辅助蒸发冷却空调系统为办公大楼提供的热舒适性评估

获取原文
获取原文并翻译 | 示例
           

摘要

The main purpose of this research is to evaluate the thermal-comfort environment in an office building served by a liquid-desiccant and indirect-and-direct evaporative-cooler-assisted 100% outdoor-air system (LD-IDECOAS). This research presents a method for evaluating the thermal environment via a series of energy simulations using the TRNSYS 17 program, integrated with an engineering equation-solver (EES) program. The supply air (SA) temperature is estimated according to the LD-IDECOAS seasonal operation modes proposed in previous research The indoor-air conditions are estimated under the assumption that the relative humidity of room air was maintained at the set values by auxiliary humidification systems. Then, the predicted mean vote (PMV) values are estimated using the given indoor environment conditions. In this paper, the indoor-air conditions and PMV values for each LD-IDECOAS operation mode are represented. A detailed analysis of the impact of the indoor-air conditions on the PMV is provided in this paper. Furthermore, the simulation results for LD-IDECOAS were compared with those for a conventional variable-air-volume (VAV) system to evaluate the thermal environment in a building served by LD-IDECOAS. The PMV values with LD-IDECOAS showed that the thermal environment in a conditioned space is generally in compliance with ASHRAE Standard 55. Consequently, it is concluded that using LD-IDECOAS in an office building can produce energy savings with an acceptable level of thermal comfort. (C) 2018 Elsevier B.V. All rights reserved.
机译:这项研究的主要目的是评估由液体干燥剂和间接和直接蒸发冷却器辅助的100%室外空气系统(LD-IDECOAS)服务的办公大楼中的热舒适环境。这项研究提出了一种使用TRNSYS 17程序并与工程方程求解器(EES)程序集成在一起的,通过一系列能量模拟来评估热环境的方法。根据先前研究中提出的LD-IDECOAS季节运行模式估算送风(SA)温度。在假定室内空气的相对湿度通过辅助加湿系统保持在设定值的前提下估算室内空气条件。然后,使用给定的室内环境条件估算预测的平均投票(PMV)值。在本文中,表示了每种LD-IDECOAS操作模式的室内空气条件和PMV值。本文提供了室内空气条件对PMV影响的详细分析。此外,将LD-IDECOAS的模拟结果与常规风量(VAV)系统的模拟结果进行了比较,以评估LD-IDECOAS服务的建筑物的热环境。 LD-IDECOAS的PMV值表明,经过调节的空间中的热环境通常符合ASHRAE标准55。因此,得出的结论是,在办公大楼中使用LD-IDECOAS可以节省能源,并具有可接受的热舒适度。 (C)2018 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号