Straw bales are used increasingly as rural building material due to their relatively low thermal conductivity and availability as a local product. The U-value is a key parameter for evaluating thermal performance of building walls. The present study investigated the effects of different structural details concerning straw bale joints (SBJs), rebar arrangements, and various finishes on U-values for SBWs using the guarded hot box method. Firstly, modification coefficient was proposed to qualitatively evaluate SBJs, results showed that R-value for straw bales without SBJs was more than three times that of straw bales with SBJs, the optimal U-value was achieved for straw bale wall (SBW) when the inner pressure was 1386 N. Secondly, for rebar arrangements, the SBW with three bars yielded the minimum U-value of 0.53 W.m(-2).K-1. Lastly, we found that plastering improved thermal performance of SBW by increasing the air tightness of the wall, and U-values for SBWs with plate tended to be larger than those with plastering attributed to that the uneven surface of the straw bales resulted in an incomplete contact between the plate and the straw bales, causing convective heat transfer, giving rise to U-values of SBWs. Thus, we recommend that clay or lime plaster should be attached to the straw bales first, before installing an exterior plate. (C) 2020 Elsevier B.V. All rights reserved.
机译:由于其具有相对较低的导热性和当地产品,秸秆捆是越来越多的农村建筑材料。 U值是用于评估建筑物墙壁的热性能的关键参数。本研究研究了使用守护的热箱方法对SBWS对SBWS的U值的不同结构细节的影响。首先,提出了修改系数以定性评估SBJ,结果表明,没有SBJ的秸秆捆包的R值超过SBJ的稻草包的三倍以上,秸秆围墙(SBW)实现了最佳的U值内部压力为1386 N.第二,对于钢筋布置,具有三个条的SBW产生0.53Wm(-2).k-1的最小U值。最后,我们发现通过增加壁的空气密封性来改善SBW的热性能,以及带板的SBW的U值倾向于涂抹于稻草包的不平坦表面导致不完整的灰泥导致的灰泥的U值板和秸秆包之间的接触,导致对流传热,从而产生SBW的U值。因此,在安装外部板之前,我们建议首先将粘土或石灰膏器连接到稻草包上。 (c)2020 Elsevier B.v.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2021年第3期|110706.1-110706.15|共15页
  • 作者单位

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Architecture Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Architecture Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Architecture Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol Sch Architecture Xian 710055 Shaanxi Peoples R China;

    Xian Univ Architecture & Technol State Key Lab Green Bldg Western China Xian 710055 Shaanxi Peoples R China|Xian Univ Architecture & Technol Sch Architecture Xian 710055 Shaanxi Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Straw bale wall; U-value; Finishes; Straw bale joints; Rebar;

    机译:稻草墙;U值;饰面;稻草捆绑;钢筋;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号