Although various cooling approaches have been proposed to overcome the thermal discomfort in residential buildings, tropical developing countries still lack affordable and effective retrofitting methods. The objective of this study was to evaluate the effectiveness of an affordable retrofitting method with high-density polyethylene (HDPE) nets as roof covers for shading over the roof, supported by full day free-running ventilation, and heat insulation above the ceiling of residential buildings in hot-humid climate regions to overcome the thermal discomfort. Field measurements were carried out in a corner terrace house in Malaysia, from September to December 2018. The roof cover with HDPE nets maintained a consistent surface temperature at the roof tiles and reduced the convective heat flux by approximately 70-80% in the attic and 88% in the room. Further, it improved the compliance (acceptability: 80%) of the whole-day mean operative temperature in the room (hot-humid climate) by 10%. The roof cover can effectively provide thermal comfort in residential buildings in Malaysia, which has a hot-humid climate. Alongside active cooling with the ceiling fan, required comfortable indoor temperature can be reached under the hot-humid climate, particularly during the night-time. Furthermore, the zero-energy-consuming, low-cost low-technology roof cover method is very suitable for low-cost houses with roof tile in hot-humid climate regions. (C) 2020 Elsevier B.V. All rights reserved.
机译:虽然已经提出了各种冷却方法来克服住宅建筑的热不适,但热带发展中国家仍然缺乏实惠且有效的改造方法。本研究的目的是评估具有高密度聚乙烯(HDPE)网的实惠改造方法的有效性,因为屋顶盖,用于在屋顶上遮蔽,由全天自由流动的通风,以及住宅天花板上方的隔热热湿润气候区的建筑物,以克服热不适。现场测量在2018年9月至12月的马来西亚的角落露台房屋中进行。带有HDPE网的屋顶盖在屋顶瓦片上保持一致的表面温度,并在阁楼和阁楼中减少了约70-80%的对流热通量。房间里88%。此外,它将整天平均手术温度的符合性(可接受性:80%)提高了10%。屋顶盖可以有效地在马来西亚的住宅建筑中有效地提供热舒适性,具有热潮气候。与吊扇的主动冷却一起,可以在热潮湿的气候下达到所需的室内温度,特别是在夜间期间。此外,零能耗低成本的低技术屋顶覆盖方法非常适合在热潮湿的气候区域中具有屋顶瓦的低成本房屋。 (c)2020 Elsevier B.v.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2020年第9期|110072.1-110072.16|共16页
  • 作者单位

    Univ Teknol Malaysia Malaysia Japan Int Inst Technol Kuala Lumpur Malaysia|Tunku Abdul Rahman Univ Coll Fac Built Environm Sch Architecture Kuala Lumpur Malaysia;

    Univ Teknol Malaysia Malaysia Japan Int Inst Technol Kuala Lumpur Malaysia;

    Kyushu Univ Interdisciplinary Grad Sch Engn Sci Fukuoka Japan;

    Tokyo City Univ Dept Restorat Ecol & Built Environm Yokohama Kanagawa Japan;

    Univ Teknol Malaysia Malaysia Japan Int Inst Technol Kuala Lumpur Malaysia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Passive cooling; Building retrofitting; Free running ventilation; Roof cover; Thermal comfort;

    机译:被动冷却;建筑改装;自由运行通风;屋顶盖;热舒适;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号