首页> 外文期刊>Energy and Buildings >Do energy performance certificates allow reliable predictions of actual energy consumption and savings? Learning from the Swiss national database
【24h】

Do energy performance certificates allow reliable predictions of actual energy consumption and savings? Learning from the Swiss national database

机译:能源绩效证书是否可以可靠地预测实际能源消耗和储蓄?从瑞士国家数据库学习

获取原文
获取原文并翻译 | 示例
           

摘要

The thermal performance gap in buildings is defined as the difference between the theoretical and the actual energy consumption for heating, and is known to undermine energy retrofit strategies and policies. This study examines the performance gap in retrofitted buildings using the Swiss Cantonal Energy Certificate for Buildings (CECB) database, using a sample of 1172 buildings for which both theoretical and actual metered consumption were known. We found an average negative performance gap of - 23% for pre-retrofit buildings (actual consumption smaller than calculated) and instead a good approximation of actual consumption with theoretical consumption after retrofitting (a positive gap of 2%). A regression analysis on the energy performance certificate input parameters characterizing the building led to the conclusion that these are poor predictors of actual consumption compared to the theoretical calculation: parameters such as the energy label and the thermal proprieties of the envelope (U values) have minor explanatory power for the actual consumption despite explaining a high degree of change in the theoretical consumption. Analysis of the indicator Energy Savings Deficit (ESD) shows an overestimation (of 37%) of the achievable savings on the basis of the theoretical consumption, whereas the prediction of savings using measured consumption before retrofit resulted in a good agreement with the actual savings (3.6% overestimation). This implies that energy savings can be estimated rather accurately by comparing the actual current consumption with the expected theoretical consumption defined by the certificate after retrofit. (c) 2020 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
机译:建筑物的热性能间隙被定义为理论和实际能量消耗之间的差异,并且已知破坏能量改造策略和政策。本研究审查了使用瑞士州州(CECB)数据库的改装建筑物的性能差距,使用1172年建筑物的样本,为此是已知理论和实际计量消耗。我们发现平均负性能差距为-23%,适用于改造式建筑物(实际消耗小于计算),而改造后的理论消耗良好的实际消耗近似(正隙为2%)。表征建筑物的能量性能证书输入参数的回归分析导致了与理论计算相比,实际消耗的预测因子差:诸如能量标签和信封(U值)的热处理(U值)的参数具有较小的参数尽管在理论消耗中解释了高度的变化,但实际消耗的解释性能力。指标节能赤字(ESD)的分析显示了基于理论消耗的可实现节省的高度估计(37%),而使用在改造之前使用测量消耗的节省预测导致实际储蓄良好( 3.6%的高度高估)。这意味着通过将实际电流消耗与经证书经过改装之后定义的预期理论消耗进行比较,可以相当准确地估计节能。 (c)2020作者。由elsevier b.v发布。这是CC By-NC-ND许可下的开放式访问文章(http://creativecommons.org/licenses/by-nc-nd/4.0/)。

著录项

  • 来源
    《Energy and Buildings》 |2020年第10期|110235.1-110235.14|共14页
  • 作者单位

    Univ Geneva Energy Efficiency Grp Inst Environm Sci Geneva Switzerland|Univ Geneva Dept FA Forel Environm & Aquat Sci Geneva Switzerland;

    Univ Geneva Energy Efficiency Grp Inst Environm Sci Geneva Switzerland|Univ Geneva Dept FA Forel Environm & Aquat Sci Geneva Switzerland;

    Swiss Fed Inst Technol Inst Technol Architecture Architecture & Bldg Syst Zurich Switzerland;

    Ecole Polytech Fed Lausanne EPFL Solar Energy & Bldg Phys Lab Lausanne Switzerland;

    Swiss Fed Inst Technol Inst Technol Architecture Architecture & Bldg Syst Zurich Switzerland;

    Univ Geneva Energy Efficiency Grp Inst Environm Sci Geneva Switzerland|Univ Geneva Dept FA Forel Environm & Aquat Sci Geneva Switzerland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Building retrofit; Actual energy consumption; Performance gap; Energy Savings Deficit;