The calculation of the ground temperature considering groundwater advection is one of the most noteworthy challenges for the simulation and design of a shallow geothermal system. This paper proposes a new method to calculate the temperature considering the groundwater advection in a scenario involving multiple ground heat exchangers and the time-variable heat flux condition. The superposition principle of the moving infinite cylindrical source solution and the moving infinite line source solution was applied in combination. Furthermore, a regression analysis was performed for various numerical calculation results obtained using a moving infinite cylindrical source model, and a simple and fast calculation solution for the problem was established. The proposed method demonstrated a maximum error of 0.0879 for the dimensionless temperature compared with the numerical calculation result. (c) 2020 Elsevier B.V. All rights reserved.
机译:考虑地下水的地面温度的计算是浅层地热系统模拟和设计的最值得注意的挑战之一。本文提出了一种在涉及多个地热交换器的场景中考虑地下水平流的新方法和时变热通量条件。组合施加移动无限圆柱源溶液和移动无限线源溶液的叠加原理。此外,对使用移动无限圆柱源模型获得的各种数值计算结果进行了回归分析,并建立了对问题的简单和快速计算解决方案。与数值计算结果相比,所提出的方法显示为无量纲温度的最大误差为0.0879。 (c)2020 Elsevier B.v.保留所有权利。