首页> 外文期刊>Energy and Buildings >A study on occupant behaviour related to air-conditioning usage in residential buildings
【24h】

A study on occupant behaviour related to air-conditioning usage in residential buildings

机译:居住建筑中与空调使用相关的乘员行为研究

获取原文
获取原文并翻译 | 示例
           

摘要

Residential buildings are typically associated with high energy consumption, especially because of airconditioning (AC) usage. Occupant behaviour can noticeably affect how an AC operates and thereby contribute to the increasing energy consumption. This problem is more pronounced with the split-type air-conditioner that is popular in South China. This study identified three representative patterns related to occupancy and AC on/off settings according to AC operation recordings from 102 bedrooms in several residential buildings of metropolitan Guangzhou, South China. Bedroom AC operation details were recorded using individual smart socket units. The resulting data showed clustering for daily on/off times, the duration of each operation, and AC 'run-over-night' probability. These clusters revealed three user-configuration patterns (i.e. night-time AC usage only (49%), both night-time and noon AC usage (6%), and low AC usage (45%)). Occupant age, total floors, and room area indices were most closely related to occupant behavioural patterns. Results indicated that AC units should be 'turned on' in timed steps when operation rates are higher than 30% or 20% to achieve acceptable thermal comfort performance. These findings should be useful for those intending to reduce overall energy consumption because the analysed schedules were based on realistic usage rather than conventional assumption (i.e. the full-time/full-space usage). (C) 2019 Elsevier B.V. All rights reserved.
机译:住宅建筑通常与高能耗有关,尤其是由于使用了空调(AC)。乘员的行为会明显影响交流电的运行方式,从而导致能耗增加。在华南地区流行的分体式空调器中,这一问题更为明显。这项研究根据中国南方广州大都市几栋住宅楼中102间卧室的交流运行记录,确定了三种与占用率和交流开/关设置有关的典型模式。使用单独的智能插座单元记录了卧室交流操作的详细信息。所得数据显示了每天开/关时间,每次操作的持续时间以及AC“夜间运行”概率的聚类。这些集群显示了三种用户配置模式(即仅夜间交流使用率(49%),夜间和中午交流使用率(6%)和低交流使用率(45%))。乘员年龄,总楼层数和房间面积指数与乘员行为模式最密切相关。结果表明,当运转率高于30%或20%时,应按时间顺序“打开”空调装置,以达到可接受的热舒适性能。这些发现对于打算减少总体能源消耗的人应该是有用的,因为所分析的时间表是基于实际使用情况而非常规假设(即,全时/全空间使用情况)。 (C)2019 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2019年第11期|109446.1-109446.13|共13页
  • 作者

  • 作者单位

    Guangzhou Univ Sch Architecture & Urban Planning 230 Guangzhou Higher Educ Mega Ctr West Outer Guangzhou Guangdong Peoples R China;

    Guangzhou Univ Sch Civil Engn 230 Guangzhou Higher Educ Mega Ctr West Outer Guangzhou Guangdong Peoples R China;

    City Univ Hong Kong Dept Architecture & Civil Engn Bldg Energy Res Grp Kowloon Tat Chee Ave Hong Kong Peoples R China;

    Guangzhou Univ Acad Bldg Energy Efficiency Guangdong Prov Key Lab Bldg Energy Efficiency & A Guangzhou Guangdong Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air-conditioning; Residential building; User behaviour; Clustering;

    机译:空调;住宅建筑;用户行为;聚类;