首页> 外文期刊>Energy and Buildings >Experimental validation of a hybrid model for vertical ground heat exchangers under on-off operation conditions
【24h】

Experimental validation of a hybrid model for vertical ground heat exchangers under on-off operation conditions

机译:开关状态下立式地面换热器混合模型的实验验证

获取原文
获取原文并翻译 | 示例
           

摘要

This work presents an experimental validation of a two-dimensional hybrid model for vertical single U-tube ground heat exchanger. It is based on the use of the electrical analogy to model heat transfer within the borehole and thermal response factors (short and long time-step g-functions) to estimate heat flow to the surrounding ground. The substitution of ground nodes with short and long-term g-functions allows the simulation with short time steps keeping the possibility of simulating periods of several years. The model was experimentally validated by using reference data sets drawn from different tests at GeoCool plant, located at the Polytechnic University of Valencia (Spain). Validation process took into account the stop-start intervals of the geothermal heat pump operation. In a test of one week with 5-min time steps, model results agree very well with experimental data achieving RMSE values smaller than 1 degrees C for output fluid temperatures. The capability of the model to reproduce vertical distribution of borehole temperature was also studied. Furthermore, a comparison with the simulated results from a refined CFD model was made. (C) 2019 Elsevier B.V. All rights reserved.
机译:这项工作提出了垂直单U型管地面换热器的二维混合模型的实验验证。它是基于使用电气类比来模拟井眼内的传热和热响应因子(短时和长时g函数)来估计流向周围地面的热量的模型。用短期和长期的g函数代替地面节点,可以以较短的时间步长进行仿真,从而保持了模拟几年的可能性。该模型已通过使用来自瓦伦西亚理工大学(西班牙)GeoCool工厂不同测试的参考数据集进行了实验验证。验证过程考虑了地热热泵运行的停止-启动间隔。在5分钟时间步长的一周测试中,模型结果与实验数据非常吻合,对于输出流体温度,RMSE值小于1摄氏度。还研究了该模型再现井眼温度垂直分布的能力。此外,与改进的CFD模型的模拟结果进行了比较。 (C)2019 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号