To analyze exactly the wave propagation processes of a transmission tower when lightning strikes, an equivalent model of a transmission tower was studied in this paper. First, based on the correlative theory of tapered antenna, an equivalent surge impedance model of a single stanchion of tower was made. This tower was regarded as a four-conductor system according to the real configuration of a tower, and the equivalent impedance of the four-conductor system was obtained by multiplying the single pillar impedance with the compensation factor. Combined with the definition of wave impedance regarded with inductance and capacitance, the compensation factor of the four-conductor system was introduced. Then, the bracings equivalent model was obtained based on the analysis of the effect of bracings on the main body of a tower, and an equivalent impedance model of the crossarms was built base on the correlation theory of the equivalent model of parallel multi-conductors. In modularizing the tower model, the equivalent impedance of the tower was found. Finally, a 500 kV tower was calculated in this paper using the equivalent impedance model of the tower.%W artykule przedstawiono badania propagacji fali w energetycznej wie?y transmisyjnej, po uderzeniu pioruna. Analiz? przeprowadzono na podstawie modu?owego modelu anteny w dwóch etapach. Najpierw stworzono model impedancyjny przepi?cia w wierzy jedno-podporowej, a nast?pnie uwzgl?dniono elementy usztywniaj?ce. Wykonano przyk?adowe obliczenia dla wie?y pracuj?cej przy napi?ciu 500 kV.
机译:为了精确地分析雷击时输电塔的波传播过程,研究了输电塔的等效模型。首先,基于锥形天线的相关理论,建立了单支柱的等效浪涌阻抗模型。根据塔的实际配置,该塔被视为四导体系统,并且四导体系统的等效阻抗是通过将单柱阻抗与补偿因子相乘而获得的。结合考虑电感和电容的波阻抗定义,介绍了四导体系统的补偿系数。然后,在分析了支柱对塔架主体的影响的基础上,得出了支柱等效模型,并基于并联多导体等效模型的相关理论,建立了横臂等效阻抗模型。在模块化塔架模型中,找到了塔架的等效阻抗。最后,本文使用塔的等效阻抗模型计算出500 kV塔。%W阿纳利兹? przeprowadzono na podstawie modu? Najpierw stworzono模型的阻抗przepi?cia w wierzy jedno-podporowej,一个女孩? Wykonano przyk?adowe obliczenia dla wie?y pracuj?cej przy napi?ciu 500 kV。

著录项

  • 来源
    《Przeglad Elektrotechniczny》 |2012年第12a期|259-263|共5页
  • 作者单位

    State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University);

    State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University),Shapingba District, Chongqing 400030, China;

    Chongqing Lightning Protection Center;

    State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University);

    State Key Laboratory of Power Transmission Equipment & System Security and New Technology (Chongqing University);

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    transmission tower; surge impedance model; electric and magnetic energy; compensation factor;

    机译:输电塔;浪涌阻抗模型电能和磁能补偿系数;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号