摘要

In low-voltage (LV) electrical networks metal-oxide varistor (MOV) surge arresters connected in parallel are often used against overvoltages. The paper presents the results of laboratory experiments, duhng which pairs of parallel connected MOV surge arresters were subjected to surges of specified energy. The tests determined energy distribution between surge arresters for AC burst voltage stresses, temperatures recorded on their surface using contact sensors and temperature distribution images (IR thermograms). The analysis of results and conclusions are also presented.
机译:在低压(LV)电网中,经常使用并联的金属氧化物变阻器(MOV)电涌放电器来防止过电压。本文介绍了实验室实验的结果,其中包括哪些成对的并联MOV电涌放电器受到了指定能量的电涌。该测试确定了电涌放电器之间的能量分布,以应对AC突发电压应力,使用接触传感器记录在其表面上的温度以及温度分布图像(红外热谱图)。还介绍了结果分析和结论。