摘要

Reactive power compensation is one of the leading ways to improve the power transmission efficiency. Currently, there is a problem of increasing the calculations accuracy for compensating devices selection and their application feasibility. The development of smart grids creates an information base that enables refined solution of such problems. We examine one of the ways to increase the accuracy in this work - it is the consideration of temperature dependence of the network resistance elements. In this case, we specify as the optimal values of power compensation devices, as payback periods. Moreover, the clarification for payback period could exceed 100%. We can apply a similar approach to other measures to reduce energy losses, and it opens up an additional field of research. We can use the results obtained in this study both as for power industrial systems, as for urban and rural distribution networks..
机译:无功补偿是提高电力传输效率的主要方法之一。当前,存在增加补偿设备选择的计算精度及其应用可行性的问题。智能电网的发展创建了一个信息库,可以完善解决此类问题。我们研究了提高这项工作精度的方法之一-这是考虑网络电阻元件的温度依赖性。在这种情况下,我们将功率补偿设备的最佳值指定为投资回收期。此外,投资回收期的澄清可能超过100%。我们可以将类似的方法应用于其他减少能源损失的措施,这开辟了更多的研究领域。我们可以将本研究中获得的结果用于电力工业系统以及城市和农村配电网络。