A simple one-dimensional transmission line model has previously been used to derive improved estimates for the transfer impedance of current transducers at high frequencies by taking account of the finite reflections that occur at the ports of the calibration fixture. This approach is further extended to take account of the additional reflections that occur in the system when an oversized calibration fixture is used. The success of this method is also assessed, for frequencies up to 600 MHz, using measured and computed results for the current induced on a wire inside a cavity backed aperture illuminated by a nearby antenna.
机译:考虑到在校准夹具的端口处发生的有限反射,以前已经使用一种简单的一维传输线模型来得出对高频电流互感器传输阻抗的改进估计。进一步扩展了此方法,以考虑到使用超大尺寸校准夹具时系统中发生的其他反射。对于频率高达600 MHz的频率,还使用在附近天线照射的腔背孔内的电线上感应的电流的测量结果和计算结果,评估了该方法的成功。