Unbalanced loading of a turbine generator induces rotor currents at twice the supply frequency, with consequent heating of solid iron and other damping circuits, which limits the negative sequence capability of the machine. The paper presents a method for analysis of rotor current and loss distributions under these conditions. Methods are described for representing the slotted region, with its combination of solid iron teeth, wedges and damping windings, and the nonlinear behaviour of currents in the solid iron of the rotor. A noteworthy feature of the analysis is the ability to include the effects of transverse flexibility slits, cut in the unslotted portion, which can give rise to extremely localised heating. The accuracy of the analysis is demonstrated by application to a 500 MW generator for which test results are available.
机译:涡轮发电机的不平衡负载会以两倍的电源频率感应出转子电流,从而导致固体铁和其他阻尼电路发热,从而限制了电机的负序能力。本文提出了一种在这些条件下分析转子电流和损耗分布的方法。描述了用于表示开槽区域的方法,该方法结合了实心铁齿,楔形和阻尼绕组以及转子实心铁中电流的非线性特性。该分析的一个值得注意的特征是能够包括在未开槽的部分中切开的横向挠性狭缝的影响,这会引起极度局部的加热。通过将其应用于可获得测试结果的500 MW发电机,可以证明分析的准确性。