首页> 外文期刊>Electric power systems research >An experimental field study of the grounding system response of tall wind turbines to impulse surges
【24h】

An experimental field study of the grounding system response of tall wind turbines to impulse surges

机译:大型风力发电机接地系统对脉冲浪涌响应的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

In this work, an experimental investigation of the grounding system behavior of tall wind turbines in both time and frequency domains is presented. Two scenarios were considered: in the first one, measurements were carried out on the grounding system embedded in the wind turbine foundation, before assembly of the wind turbine itself; in the second one, the complete wind turbine (tower, nacelle and blades) was included. The study also presents an enhanced signal processing technique for noise cancelation in a harsh electromagnetic environment. In the analysis, the frequency dependence of the grounding impedance was evaluated and a numerical simulation in steady state was performed. The simulation model leads to a satisfactory representation of the studied system. Preliminary results show that the evaluated grounding impedance is not significantly affected by the presence of the complete wind turbine at the evaluated frequencies. (C) 2018 Elsevier B.V. All rights reserved.
机译:在这项工作中,提出了在时域和频域上对高层风力发电机接地系统性能的实验研究。考虑了两种情况:在第一种情况下,在组装风机本身之前,对嵌入风机基础中的接地系统进行了测量;在第二个中,包括完整的风力涡轮机(塔,机舱和叶片)。该研究还提出了一种增强的信号处理技术,用于在恶劣的电磁环境中消除噪声。在分析中,评估了接地阻抗的频率依赖性,并进行了稳态数值模拟。仿真模型导致研究系统的令人满意的表示。初步结果表明,在评估频率下,完整风力涡轮机的存在不会显着影响评估接地阻抗。 (C)2018 Elsevier B.V.保留所有权利。