摘要

Due to the voltage security uncertainty caused by construction sequence in multi-stage transmission expansion planning (MTEP) in bulk power grids, it is necessary to appropriately arrange the construction sequence of the MTEP schemes to reduce voltage security risk. The Gini coefficient is widely used to weigh the gap of residents' income distribution. In this paper, the voltage security Gini coefficient is defined as the voltage security risk index of the MTEP scheme, and is presented to quantitatively evaluate the entire voltage security of one MTEP scheme. Voltage security evaluation model of the MTEP is established based on voltage security Gini coefficient. Compared to the stabilization cost, the proposed model directly reflects the voltage security of the MTEP scheme, and the local optimum is avoided. The presented method is applied on the IEEE 118-bus 54-generator test system. Results show the validity and effectiveness of the proposed model.
机译:由于散装电网的多级输电扩展计划(MTEP)中的施工顺序导致电压安全性不确定,因此有必要适当安排MTEP方案的施工顺序以降低电压安全风险。基尼系数被广泛用来衡量居民收入分配的差距。本文将电压安全性基尼系数定义为MTEP方案的电压安全性风险指标,并提出以定量评估一种MTEP方案的整体电压安全性。基于电压安全基尼系数建立了MTEP的电压安全评估模型。与稳定成本相比,该模型直接反映了MTEP方案的电压安全性,避免了局部最优。提出的方法应用于IEEE 118-bus 54发电机测试系统。结果表明了该模型的有效性和有效性。