High-voltage direct current (HVDC) system is difficult to proliferate due to the absence of a useful brake for the HVDC circuit breaker. To overcome this problem, this study proposes a useful brake, termed as an Eddy current brake (EB). A time-consuming time step analysis using the finite element method (FEM) is required to analyse the EB. To address this problem, a rapid and accurate analysis method is proposed using the equivalent circuit model, equation of motion, and the Runge-Kutta method. This technique is termed as the EER method in this research. The characteristic of the EB is analysed by using the proposed EER method and the results are compared with those of the 2D FEM analysis. The usefulness of the proposed EER method with regard to accuracy and rapidness is confirmed via 2D FEM analysis.
机译:由于缺少用于HVDC断路器的有用制动器,因此高压直流(HVDC)系统难以扩散。为了克服这个问题,这项研究提出了一种有用的制动器,称为涡流制动器(EB)。需要使用有限元方法(FEM)进行耗时的时间步分析才能分析EB。为了解决这个问题,提出了一种使用等效电路模型,运动方程和Runge-Kutta方法的快速而准确的分析方法。该技术在本研究中被称为EER方法。使用提出的EER方法分析了EB的特性,并将结果与​​2D FEM分析的结果进行了比较。通过二维有限元分析证实了所提出的EER方法在准确性和快速性方面的有用性。