首页> 外文期刊>Documenta Ophthalmologica >Macular function assessed with mfERG before and after panretinal photocoagulation in patients with proliferative diabetic retinopathy
【24h】

Macular function assessed with mfERG before and after panretinal photocoagulation in patients with proliferative diabetic retinopathy

机译:增生性糖尿病视网膜病变患者全视网膜光凝前后mfERG评估黄斑功能

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To examine macular function and its correlation to macular thickness before and after panretinal photocoagulation for proliferative retinopathy in diabetic patients. Methods: Ten diabetic patients (aged 57 ± 10 years, diabetes duration 21 ± 10 years) treated with panretinal photocoagulation outside the great vascular arcade underwent multifocal electroretinography (mfERG) and optical coherence tomography (OCT) before and 6 months after treatment. When focal treatment in the macular region was performed prior to panretinal photocoagulation the investigations took place 3 weeks after this treatment but before the panretinal photocoagulation. One eye per patient was examined. Amplitudes and implicit times of the mfERG response were analyzed within the four innermost (27°) of the six concentric rings registered by the mfERG, which corresponds to the area measured by the OCT (Ø 3.5 mm). Results: Visual acuity was similar before and after photocoagulation, 1.0; 0.7–1.0 (md, range) versus 1.0; 0.6–1.0 (md, range). The mean values of the ring average amplitudes were reduced in the first and second, third and fourth concentric rings from foveola after photocoagulation, p= 0.001, p= 0.011 and p= 0.004, respectively. No change was seen in implicit time after treatment. OCT values were similar before and after photocoagulation. There was no correlation between retinal thickness assessed with OCT and amplitudes measured by the mfERG. Conclusion: In spite of unchanged values of retinal thickness and visual acuity, panretinal photocoagulation seems to cause a functional impairment in the adjacent untreated macula, shown by reduced amplitudes measured by the mfERG.
机译:目的:探讨糖尿病患者全视网膜光凝前后黄斑功能及其与黄斑厚度的相关性。方法:对10例糖尿病患者(年龄57±10岁,糖尿病病程21±10年)在大血管拱门外进行全视网膜光凝治疗,在治疗前后分别进行了多焦点视网膜电图(mfERG)和光学相干断层扫描(OCT)。当在全视网膜光凝之前在黄斑区进行局部治疗时,研究在该治疗后3周但在全视网膜光凝之前进行。每位患者检查一只眼睛。在由mfERG记录的六个同心环的四个最里面(27°)内分析了mfERG响应的幅度和隐式时间,这对应于OCT测量的面积(Ø3.5 mm)。结果:光凝前后视力相似,为1.0; 0.7-1.0(md,范围)对1.0; 0.6–1.0(md,范围)。在光凝之后,来自黄斑的第一,第二,第三和第四同心环的环平均振幅平均值降低,分别为p = 0.001,p = 0.011和p = 0.004。治疗后的内隐时间未见变化。光凝前后的OCT值相似。用OCT评估的视网膜厚度与mfERG测得的振幅之间没有相关性。结论:尽管视网膜厚度和视敏度值不变,但通过mfERG测得的振幅降低显示,视网膜光凝似乎会在未治疗的黄斑附近引起功能损害。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号