...
首页> 外文期刊>Documenta Ophthalmologica >Influence of Recording Electrode Type and Reference Electrode Position on the Canine Electroretinogram
【24h】

Influence of Recording Electrode Type and Reference Electrode Position on the Canine Electroretinogram

机译:记录电极类型和参考电极位置对犬视网膜电图的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Electroretinography is commonly used to assess the functional integrity of the retina. There are many external variables that can influence the electroretinographic waveforms recorded, and it is important to be aware of these so as not to misinterpret their effects as abnormalities in retinal function. In this study we examined the effect of three different recording electrodes on the ERGs recorded from normal dogs. A bipolar Burian–Allen lens, a monopolar Dawson Trick Litzkow (DTL) fiber electrode, and a monopolar ERG-Jet lens electrode were compared. The effect of altering the distance of the reference electrode from the eye was also examined; using the ERG-Jet lens electrode, the ERG was recorded with the reference electrode placed over the zygomatic arch at 1, 3 and 5 cm caudal to the lateral canthus. The ERGs recorded with the bipolar Burian–Allen lens had significantly lower amplitudes, higher a-wave thresholds and a shallower initial a-wave slope, than those recorded by the two monopolar electrodes. Positioning the reference electrode further from the eye resulted in significantly higher amplitudes. Naka-Rushton fitting and calculation of retinal sensitivity (K) gave significantly different results between the Burian–Allen lens and ERG-Jet lens electrode with the reference electrode 5 cm from the lateral canthus. These results demonstrate that recording electrode type and distance of the reference electrode from the eye significantly affect the ERG tracings of the dog, and may alter the assessment of retinal function that can therefore be derived. Results obtained using these three different types of electrodes cannot be directly compared.
机译:视网膜电图检查通常用于评估视网膜的功能完整性。有许多外部变量会影响所记录的视网膜电图波形,因此务必要意识到这一点,以免将其影响误认为是视网膜功能异常。在这项研究中,我们检查了三种不同的记录电极对正常狗记录的ERG的影响。比较了双极Burian-Allen透镜,单极Dawson Trick Litzkow(DTL)纤维电极和单极ERG-Jet透镜电极。还检查了改变参比电极到眼睛的距离的影响。使用ERG-Jet透镜电极,记录ERG,将参比电极放在arch突外侧1、3和5 cm处的弓上。与两个单极电极所记录的相比,用双极Burian–Allen透镜记录的ERG的幅度明显更低,a波阈值更高且初始a波斜率更浅。将参比电极放置在距眼睛较远的位置,会导致振幅明显升高。 Naka-Rushton拟合和视网膜敏感度(K)的计算在Burian–Allen晶状体电极和ERG-Jet晶状体电极之间(参比电极距can侧眼5 cm)产生了明显不同的结果。这些结果表明,记录电极的类型和参比电极与眼睛的距离会显着影响狗的ERG描记,并且可能会改变由此得出的视网膜功能评估。使用这三种不同类型的电极获得的结果无法直接进行比较。

著录项

  • 来源
    《Documenta Ophthalmologica》 |2005年第2期|95-106|共12页
  • 作者单位

    Department of Small Animal Clinical Sciences College of Veterinary Medicine Michigan State University;

    Department of Small Animal Clinical Sciences College of Veterinary Medicine Michigan State University;

    Department of Small Animal Clinical Sciences College of Veterinary Medicine Michigan State UniversityDepartment of Veterinary Medicine Federal University of Paraná;

    Department of Small Animal Clinical Sciences College of Veterinary Medicine Michigan State University;

    Department of Small Animal Clinical Sciences College of Veterinary Medicine Michigan State University;

    Department of Small Animal Clinical Sciences College of Veterinary Medicine Michigan State UniversityDepartment of Small Animal Clinical Sciences D-208 Veterinary Medical Center;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    dog; electroretinogram; recording electrode; retina; variability;

    机译:狗;视网膜电图;记录电极;视网膜;变异性;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号