首页> 外文期刊>IEEE Transactions on Dielectrics and Electrical Insulation >Partial Discharge Signal Interpretation for Generator Diagnostics
【24h】

Partial Discharge Signal Interpretation for Generator Diagnostics

机译:发电机诊断的局部放电信号解释

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Several common sources of discharges activity occurring on generators have been replicated in the laboratory under well-controlled conditions. Each source was evaluated individually and recorded with a phase resolved acquisition system and with a spectrum analyzer. The dominant features of each respective phase resolved partial discharge (PRPD) pattern are presented. The frequency content of the discharge signal at the detection coupler was also investigated. The association of each well-defined type of discharge source, with its specific PRPD pattern, constitutes the basis of our database used for the discharge source recognition during generator diagnostics. The comparison of laboratory results with actual field measurements gathered over the last decade is summarized in this paper.
机译:在良好控制的条件下,实验室中已复制了发电机上发生的几种常见放电活动来源。每个信号源均经过单独评估,并使用相位分辨采集系统和频谱分析仪进行记录。提出了每个相分辨局部放电(PRPD)模式的主要特征。还研究了检测耦合器处放电信号的频率含量。每种定义明确的放电源类型及其特定的PRPD模式的关联,构成了我们用于发电机诊断过程中识别放电源的数据库的基础。本文总结了过去十年中实验室结果与实际现场测量结果的比较。