首页> 外文期刊>Dielectrics and Electrical Insulation, IEEE Transactions on >Reclaiming of in-service natural ester-based insulating fluids
【24h】

Reclaiming of in-service natural ester-based insulating fluids

机译:回收使用中的基于天然酯的绝缘液

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The degradation of in-service natural ester-based insulating fluid could result in oil viscosity, acidity and dissipation factor increases. In this work, natural ester-based insulating fluid samples aged in the laboratory and in-service (collected from a Recloser) were reclaimed with different adsorbent materials. All the tested samples showed some properties above the provisional limit for triggering prompt additional investigation suggested by the IEEE guide for in-service natural ester fluids, such as viscosity increase >; 10% from value at time of initial energization, acid number >; 0.3 mg KOH/g or dissipation factor at 25°C >; 3%. The reclamation process was accomplished by the use of two methods: 1) by mechanical agitation of the aged oil in the presence of several adsorbents and 2) by percolation of the aged oil through the adsorbent material. The reclaimed fluids were monitored by evaluation of viscosity, acid number and dissipation factor and the results were compared with unused oil. The results showed that viscosity is the main criterion to evaluate whether or not in-service natural ester-based insulating fluid can be reclaimed.
机译:使用中的基于天然酯的绝缘液的降解可能导致油的粘度,酸度和耗散因数增加。在这项工作中,使用不同的吸附剂材料回收了在实验室和使用中老化的天然酯基绝缘液样品(从Recloser收集)。所有测试的样品均显示出一些特性,这些特性超出了IEEE指南针对使用中的天然酯油所建议的触发即时补充研究的临时限制,例如粘度增加>;。初始通电时的值的10%,酸值>; 0.3 mg KOH / g或25°C时的耗散系数>; 3%。回收过程通过以下两种方法完成:1)在几种吸附剂的存在下,通过机械搅拌陈旧的油,以及2)通过陈旧的油通过吸附剂的渗透来完成。通过评估粘度,酸值和耗散因子来监测回收的流体,并将结果与​​未使用的油进行比较。结果表明,粘度是评估是否可以回收使用中的天然酯基绝缘液的主要标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号