首页> 外文期刊>IEEE Transactions on Dielectrics and Electrical Insulation >Dielectric response characterization of in-service aged sheds of (U) HVDC silicone rubber composite insulators
【24h】

Dielectric response characterization of in-service aged sheds of (U) HVDC silicone rubber composite insulators

机译:(U)HVDC硅橡胶复合绝缘子在役老化棚的介电响应特性

获取原文
获取原文并翻译 | 示例
           

摘要

Investigations of bulk dielectric properties of specimens extracted from in-service aged and aged UHVDC composite insulator sheds are reported in this paper. The program of the study included measurements of DC conductivity and complex permittivity at frequency range 10−4–103 Hz at various temperatures in dry and wet (water immersion) conditions. The obtained results are analyzed by considering a combination of relations describing various dielectric relaxation modes in dielectrics, included three Cole-Cole types of responses and a hopping process. The hopping has the strongest impact on the responses in the whole frequency range. Two of the Cole-Cole responses appearing in the low frequency range are attributed to Maxwell-Wagner-Sillars relaxations at macroscopic and mesoscopic levels; first one representing interfacial polarization at the border between specimen and air gap in the electrode arrangement, while the second one is attributed to the charge relaxation at filler boundaries and internal cavities in the polymeric materials. The third Cole-Cole process, active at higher frequencies, is considered as a sign of polymer degradation, as it shifts with the ageing to higher frequencies. Based on the results of this study, it is claimed that dielectric response measurements on specimens of in-service aged composite insulator sheds can provide useful information on the degree of material degradation. In addition, a water immersion test in combination with such measurements may be a good way to enhancing the observed changes.
机译:本文报道了从在役老化和老化的UHVDC复合绝缘子棚中提取的标本的整体介电性能的研究。该研究计划包括在干湿(水浸)条件下的各种温度下,在10−4–103 Hz频率范围内测量直流电导率和复介电常数。通过考虑描述电介质中各种介电弛豫模式的关系的组合来分析获得的结果,包括三种Cole-Cole类型的响应和一个跳跃过程。跳变对整个频率范围内的响应影响最大。低频范围内出现的两个Cole-Cole响应归因于宏观和介观水平的Maxwell-Wagner-Sillars弛豫。第一个代表电极布置中样品和气隙之间边界处的界面极化,而第二个则归因于填充剂边界处的电荷弛豫和聚合物材料中的内腔。在较高的频率下活跃的第三个Cole-Cole工艺被认为是聚合物降解的迹象,因为它会随着老化而转移到较高的频率。根据这项研究的结果,据称在役老化复合绝缘子棚样品的介电响应测量可以提供有关材料降解程度的有用信息。此外,将水浸测试与此类测量结合使用可能是增强观察到的变化的好方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号