摘要

HVDC transmission has been adopted widely for its large energy transport capacity, high stability and more economical in long-distance power transmission. Converter transformer is the key equipment in HVDC transmission system. The insulation of converter transformer valve side endures a composite voltage including AC, DC and pulsating component etc. Partial discharge (PD) occurring in a void surrounded by insulating material is believed to be one of the main causes of insulation breakdown and it is the main factor of electrical aging of materials. Therefore, it is important to recognize the prebreakdown phenomena and to evaluate the lifetime of insulating materials. Much research has been carried out to study the partial discharge characteristics under pure AC or DC voltage. Only a few investigations were focused on composite voltage. In order to obtain more understanding of PD characteristics under composite voltage, the PD detection and analysis of oil-pressboard insulation under pulsating DC voltage waveform are studied in this paper. The voltage waveform of converter transformer is analyzed through computer simulation. A 6-pulse DC voltage generator and PD detection system are set up. Influence of the DC component and pulsating component to the PD characteristics is studied in lab test. The experimental results show the DC component and pulsating component affect the PD inception voltage, but the pulsating component has more significant influence to PD characteristics than DC component. The study provides an experimental foundation for the converter transformer insulation breakdown mechanism analysis.
机译:高压直流输电以其大的能量传输能力,高的稳定性和长距离输电的经济性而被广泛采用。换流变压器是高压直流输电系统的关键设备。换流变压器阀侧的绝缘层承受包括AC,DC和脉动分量等的复合电压。在绝缘材料包围的空隙中发生的局部放电(PD)被认为是绝缘击穿的主要原因之一,并且是主要原因材料电老化的因素。因此,认识到预击穿现象并评估绝缘材料的寿命很重要。为了研究纯交流或直流电压下的局部放电特性,已经进行了大量研究。只有很少的研究集中在复合电压上。为了对复合电压下的局部放电特性有更多的了解,本文研究了脉动直流电压波形下油压板绝缘子的局部放电检测和分析。通过计算机仿真分析了换流变压器的电压波形。建立了一个六脉冲直流电压发生器和局部放电检测系统。在实验室测试中研究了直流分量和脉动分量对局部放电特性的影响。实验结果表明,直流分量和脉动分量影响PD的起始电压,但脉动分量对PD特性的影响要大于直流分量。该研究为换流变压器绝缘击穿机理的分析提供了实验基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号