...
首页> 外文期刊>BMC Oral Health >Three-dimensional alveolar bone assessment of mandibular molars for immediate implant placement: a virtual implant placement study
【24h】

Three-dimensional alveolar bone assessment of mandibular molars for immediate implant placement: a virtual implant placement study

机译:立即植入物放置下颌臼齿的三维肺泡骨评估:虚拟植入物放置研究

获取原文
           

摘要

To elucidate the anatomical features of the mandibular molar region to allow safe immediate implant placement. Cone-beam computed tomography images of 150 patients (600 teeth) were reviewed retrospectively. The virtual implants were placed in the mandibular first and second molar region. The anatomic structures of the mandible and inter-radicular septum were both categorized into three types. The relationship between implant and inferior alveolar nerve (IAN), and the horizontal distance from the implant surface to the bone wall were analyzed. Variables were compared using a student’s t-test, or Mann–Whitney U test. Type U (39.0%) and type S (56.0%) were the most common in the first molar, while type U (67.7%) and type M (54.7%) had the highest prevalence rate in the second molar. The mean distance from the level where the virtual implant was completely surrounded by bone to IAN was 7.06?mm. The mean horizontal widths from the implant to the mesial and distal socket wall were 1.59?mm and 1.89?mm. The widths of the inter-radicular septum and the distances from implant to the buccal and lingual plate on different sections were significantly associated with tooth position (P??.05). In the first molar region, the implant is suggested to be placed in the center of the inter-radicular septum, while in the second molar region, the mesial root socket could be considered. Immediate implant placement in the mandibular second molar sockets shows a high risk of IAN injury, lingual perforation, and inadequate primary stability.
机译:为了阐明下颌摩尔地区的解剖学特征,以允许安全立即植入物放置。回顾性地审查了150名患者(600颗牙齿)的锥梁计算断层扫描图像。虚拟植入物置于下颌第一和第二磨牙区。下颌和自治区间隔的解剖结构均分为三种类型。分析了植入物和下牙槽神经(IAN)的关系,以及从植入物表面到骨壁的水平距离。使用学生的T检验或Mann-Whitney U测试进行比较变量。 u(39.0%)和S型(56.0%)在第一磨牙中最常见,而型U(67.7%)和M型(54.7%)在第二摩尔中具有最高的流行率。距离虚拟植入物完全被骨围绕IAN包围的水平的平均距离为7.06Ωmm。来自植入物到薄层和远端插座壁的平均水平宽度为1.59Ωmm和1.89?mm。与牙齿位置(p≤0.05)显着相关(P = 0. 05)显着相关的间隔子和植入物到颊板的距离和舌板的距离和距离。在第一磨牙区中,建议将植入物放置在自由基间隔内的中心,而在第二摩尔区域中,可以考虑界面根插座。下颌第二磨砂插座中的立即植入物放置显示IAN损伤,舌孔穿孔和初级稳定性不足的高风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号