首页> 外文期刊>AIP Advances >First direct comparison of whole beam and single beamlet divergences in a negative ion source with simultaneous BES and CFC tile calorimetry measurements
【24h】

First direct comparison of whole beam and single beamlet divergences in a negative ion source with simultaneous BES and CFC tile calorimetry measurements

机译:具有同声BES和CFC瓦片量热法测量的负离子源中整个梁和单束分流的整个梁和单束分歧的首先直接比较

获取原文
           

摘要

Neutral beam injection (NBI) systems are required for heating and current drive in the next generation fusion experiment ITER, and strict requirements are placed on the beamlet core divergence (7 mrad) for transmission into the tokamak. The measurement of single beamlet divergence is challenging due to the multi-beamlet nature of the negative ion sources that are required for such systems; diagnostic systems compatible with large high power ion beams can only provide spatially averaged measurements, leading to mixing of beamlet signals within diagnostic results. To improve the understanding of this effect, a direct comparison has been made between the single beamlet and multi-beamlet divergence by a combination of both Beam Emission Spectroscopy (BES) and 1D carbon fiber composite tile calorimetry, in a joint campaign by IPP and Consorzio RFX. The measurements performed so far in this campaign at the BATMAN Upgrade Test Facility have led to two major results. First, an excellent agreement is found for single beamlet divergences from the two diagnostics, showing that the results from these diagnostic systems can be compared for single beamlets. Second, the contribution of beamlet deflection, caused by an alternating magnetic field at the extract grid, to the divergence as measured using BES has been quantified with up to a factor of 3 increase when compared with the single beamlet value. This demonstrates that further investigation is needed into how mixing of information from a beamlet affects diagnostic results with a combination of both simulation and experiment, which will be performed in a next step.
机译:中性光束注射(NBI)系统是在下一代融合实验中的加热和电流驱动器所需的,并且严格的要求放置在光束核心发散(< 7MRad)上进行传输到Tokamak中。由于这种系统所需的负离子源的多束性质,单束分发散的测量是具有挑战性的;与大型高功率离子束兼容的诊断系统只能提供空间平均测量,从而导致诊断结果中的束信号的混合。为了提高对这种效果的理解,通过IPP和Consorzio的联合运动中,通过光束发射光谱(BES)和1D碳纤维复合瓦片量热法在单一小束和多束分歧之间进行直接比较RFX。到目前为止在蝙蝠侠升级测试设施的这项运动中进行的测量导致了两个主要结果。首先,找到了来自两个诊断的单束分流的优秀协议,表明可以比较来自这些诊断系统的结果以比较单个小区。其次,由提取物网格处的交替磁场引起的小束偏转的贡献,以使用BES测量的发散,随着单个波束值的比较,在多达3倍的增加时被量子化。这表明需要进一步的调查,以如何通过模拟和实验的组合影响来自光束的信息的混合影响诊断结果,这将在下一步骤中进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号