...
首页> 外文期刊>Frontiers in Medicine >Corneal Densitometry After Small Incision Lenticule Extraction (SMILE) and Femtosecond Laser-Assisted LASIK (FS-LASIK): 5-Year Prospective Comparative Study
【24h】

Corneal Densitometry After Small Incision Lenticule Extraction (SMILE) and Femtosecond Laser-Assisted LASIK (FS-LASIK): 5-Year Prospective Comparative Study

机译:角膜致密度测定小切口胶凝式萃取(微笑)和飞秒激光辅助LASIK(FS-LASIK):5年的前瞻性比较研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To investigate long-term changes in corneal densitometry (CD) following small incision lenticule extraction (SMILE) vs. femtosecond laser-assisted LASIK (FS-LASIK) in patients with myopia or myopic astigmatism. Methods: Prospective analysis was performed in 66 eyes of 38 patients (13 males) who underwent SMILE and 54 eyes of 29 patients (5 males) who underwent FS-LASIK. In all patients, an ocular examination was performed preoperatively, and at 6–12 months and 5 years postoperatively. CD was obtained with the Pentacam Scheimpflug imaging system at the 0–2-mm, 2–6-mm, and 6–10-mm zones of the cornea at depth of anterior 120 μm, midcornea, and posterior 60 μm. Correlation analysis was performed between postoperative change in CD and other variables such as age, type of surgery, central corneal thickness, spherical equivalent, lenticule thickness/ablation depth, and changes in wavefront aberrations. Results: At postoperative 6–12 months, a significant reduction at several corneal zones in the FS-LASIK cohort ( P 0.05) was observed. In the SMILE cohort, no significant change in CD relative to baseline was observed. However, at 5 years postoperatively, in both groups, a significant decrease in CD was observed in three zones of three layers (all P 0.001). The change in CD was similar between groups at postoperative 6–12 months, but at 5 years the magnitude of change was significantly smaller in SMILE than FS-LASIK in the anterior and central layers (all P 0.05). Conclusion: CD with the Scheimpflug imaging system showed a significant decrease at 5 years after SMILE or FS-LASIK, and the change was significantly less pronounced after SMILE.
机译:目的:在近视或近视患者患者中调查角膜密度测定术(CD)的长期变化,术后近视患者患者的FEMTOSECOND激光辅助LASIK(FS-LASIK)。方法:前瞻性分析是在66名患者(13名男性)的66只眼中进行的,接受过笑脸和54名患者(5名男性)的54只患者(5名男性)。在所有患者中,术前和术后6-12个月和5年进行眼检查。在0-2毫米,2-6mm和6-10mm区域的偏萨克姆Scheimpflum成像系统处在前卫120μm,中躯和后部60μm的深度的0-2mm,2-6mm和6-10mm区域中获得Cd。在CD和其他变量的术后变化之间进行相关分析,例如年龄,手术类型,中央角膜厚度,球面等效,晶格厚度/消融深度,以及波前像差的变化。结果:在术后6-12个月,在FS-LASIK队列(P <0.05)中的几个角膜区域的显着减少。在微笑队列中,观察到相对于基线的CD没有显着变化。然而,在术后5年,在两组中,在三个层的三个区域中观察到CD的显着降低(所有P <0.001)。在术后6-12个月的群体之间的群体之间的变化在术后6-12个月之间相似,但在5年后,笑容比前部和中央层中的FS-LASIK更小的变化幅度明显更小(所有P <0.05)。结论:CD与Scheimpflug成像系统在微笑或FS-LASIK后5年显示出显着降低,微笑后的变化显着较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号