首页> 外文期刊>Current Eye Research >Corneal Densitometry after Femtosecond Laser-Assisted In Situ Keratomileusis (Fs-LASIK) and Small Incision Lenticule Extraction (SMILE)
【24h】

Corneal Densitometry after Femtosecond Laser-Assisted In Situ Keratomileusis (Fs-LASIK) and Small Incision Lenticule Extraction (SMILE)

机译:Mevtosecond激光辅助后的角膜密度测定法(FS-LASIK)和小切口叮当提取(微笑)

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To compare corneal densitometry values after Femtosecond Laser-Assisted In Situ Keratomileusis (Fs-LASIK) and Small Incision Lenticule Extraction (SMILE) using Scheimpflug Imaging.Methods: Our retrospective clinical trial included a total of 146 eyes where 57 eyes underwent Fs-LASIK and 89 eyes underwent SMILE. Examinations with a Pentacam Scheimpflug device (Oculus, Wetzlar, Germany) were performed before surgery, 1week, 1month, 3months, 6months, and 1year after surgery. Detailed data of all four concentric optical zones were acquired - central 0-2 mm, 2-6 mm, 6-10 mm and 10-12 mm. The cornea was divided into anterior 120 mu m, middle and posterior 60 mu m sections. Values were analyzed during follow-up comparing Fs-LASIK and SMILE.Results: No statistically significant differences in corneal density were detected. The central 0-2 mm anterior area demonstrated a mean 1-year value of 17.99 grayscale units (GSU) 0.89 (range 16.60-19.50) after Fs-LASIK versus 17.96 GSU +/- 0.98 (range 16.40-20.00) after SMILE. Three months after surgery there was a slight temporary density increase in the 6-10mm anterior annulus in the LASIK group - 22.19 (SD=3.99, range: 15.60-30.50) compared to SMILE - 20.39 (SD=3.79, range 14.70-36.30).Conclusion: There were no statistically significant short or long-term differences in postoperative corneal densitometry after LASIK and SMILE, demonstrating SMILE is not inferior in this regard. Known delayed visual acuity recovery after SMILE in relation to LASIK could not be correlated with changes in corneal density.
机译:目的:使用Scheimpflug映像进行Femtosecond激光辅助后的角膜致密度值LASIK和89只眼睛接受了微笑。在手术后,1周,1个月,3个月,6个月和1年进行手术前进行与宾馆Scheimpflug设备(Oculus,Wetzlar,德国)进行检查。获得所有四个同心光带的详细数据 - 中央0-2 mm,2-6毫米,6-10mm和10-12mm。角膜被分成前部120μm,中间和后部60μm部分。在比较FS-LASIK和SMILE期间在随访期间分析了值。结果:检测到角膜密度没有统计学上显着的差异。 0-2 mm前区域的中央6.9.99(GSU)的平均值为17.99级(GSU)0.89(范围为16.60-19.50),微笑后17.96 GSU +/- 0.98(范围为16.40-20.00)。手术三个月后,LASIK组6-10mm前环的略微临时密度增加 - 22.19(SD = 3.99,范围:15.60-30.50)与微笑 - 20.39(SD = 3.79,范围14.70-36.30)结论:在LASIK和微笑之后,术后角膜密度测定法没有统计上显着的短期或长期差异,在这方面展示了微笑并不逊色。与LASIK相关的微笑后的已知延迟视力恢复与角膜密度的变化不相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号