A novel internal cold circulation radiofrequency-assisted device for liver transection

机译:一种新型冷循环射频辅助装置,用于肝横截面

获取原文
           

摘要

Purpose To evaluate the safety and efficacy of a new internal cold circulation bipolar radiofrequency compared with Habib-4X bipolar radiofrequency device in the resection of liver tumors. Methods A total of 85 patients with hepatocellular carcinoma who received radiofrequency-assisted liver resection from February 2017 to January 2020 were retrospectively enrolled in our study, in which 45 patients received the new internal cold circulation bipolar radiofrequency (New-RF) and 40 patients received Habib-4X bipolar radiofrequency (Habib-4X). Primary outcome measures were the speed of liver transection, the width of coagulation tissue, hemorrhage volume, blood transfusion rate, and operation time. Results The baseline characteristics of patients in the New-RF and Habib-4X groups had no significant difference ( p ?0.05). Compared to Habib-4X, the New-RF had a faster average speed of liver transection (4.81?±?1.20?cm 2 /min vs 3.64?±?1.08?cm 2 /min, p ?0.001), a narrower width of coagulation tissue (1.42?±?0.23?cm 2 vs 1.81?±?0.20?cm 2 , p ?0.001), a less operation time (55.04?±?16.12?min vs 64.02?±?15.09?min, p =?0.010), a lower rate of needle path bleeding (13.3% vs 35.0%, p =?0.019), and a lower carbonization rate of electrode needle (22.2% vs 77.8%, p ?0.001). Hemorrhage during the transection (85.0?ml vs 105.0?ml, p =?0.438) and hemorrhage per square centimeter (3.28?±?0.86?ml/cm 2 vs 3.60?±?1.12?ml/cm 2 , p =?0.141) in the New-RF group were smaller than those in Habib-4X group with no significant difference. Conclusion The new internal cold circulation bipolar radiofrequency was a safe and efficacious auxiliary device for liver resection with a faster speed of resection, lower carbonization rate of electrode needle, and more precise range of coagulation.
机译:目的是评估新的内部冷循环双极射频的安全性和功效与Habib-4x双极射频装置在切除肝肿瘤中相比。方法对2017年2月至1月2020年1月期间,共有85例肝细胞癌患有85例肝细胞癌,他们回顾性研究了我们的研究,其中45名患者接受了新的内部冷循环双极射频(新RF)和40名患者接受了40名患者Habib-4x双极射频(Habib-4x)。主要结果措施是肝横衰竭的速度,凝血组织的宽度,出血量,输血率和操作时间。结果新射频和Habib-4x组患者的基线特征无显着差异(P> 0.05)。与Habib-4x相比,新RF的平均肝横扫速度更快(4.81?±1.20?cm 2 / min与3.64?±1.08?mc 2 / min,p& 0.001),更窄凝血组织的宽度(1.42?±±0.23Ω·cm 2与1.81?±0.20?cm 2,P& 0.001),操作时间较少(55.04?±16.12?min与64.02?±15.09?min ,P = 0.010),针路径出血的较低速率(13.3%Vs 35.0%,p = 0.019),电极针的较低碳化速率(22.2%vs 77.8%,p <0.001)。在横截面期间出血(85.0毫升与105.0?ml,p = 0.438)和每平方厘米出血(3.28?±0.86?ml / cm 2与3.60?±1.12?ml / cm 2,p = 0.141 )在新RF组中小于Habib-4x组那些没有显着差异的。结论新的内部冷循环双极射频是一种安全且有效的辅助装置,用于肝切除速度更快,电极针的碳化率降低,更精确的凝血。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号