...
首页> 外文期刊>BMC Surgery >Management of high-energy tibial shaft fractures using the hexapod circular external fixator
【24h】

Management of high-energy tibial shaft fractures using the hexapod circular external fixator

机译:使用六角孔圆形外固定器管理高能量胫骨轴骨折

获取原文
           

摘要

The hexapod external fixator (HEF) is increasingly used for high-energy tibial shaft fracture care as more general orthopedic surgeons are gaining expertise of this versatile device. The purpose of this study was to evaluate the clinical effectiveness of the HEF for definitive management in patients with high-energy tibial shaft fractures. The study was conducted on 34 patients with tibial shaft fractures who were admitted or referred to our institution and consented to HEF treatment from Jan 2016 to June 2019, including 27 males and 7 females with a mean age of 39?years (range 18 to 65?years). Patients' clinical and radiological data, and the final clinical outcomes at a minimum of 12?months follow-up were collected and retrospectively analyzed. All complications were documented according to Paley’s classification. The clinical outcomes were evaluated using the Association for the Study and Application of the Method of Ilizarov criteria (ASAMI) at the last clinical visit. All patients remained in the HEF for a mean of 26?weeks (range 15 to 52?weeks) and acquired complete bone union. The satisfactory alignment was achieved in all patients, and all the patients were able to perform daily activities with no difficulty at the last clinical visit. Complications included pin tract infection (44%), delayed union (6%), nonunion (3%), and joint stiffness (3%). The ASAMI bony result was excellent in 31 patients and good in 3. The ASAMI functional result was excellent in 27 patients, good in 6, and fair in 1. Definitive management using the hexapod external fixator is an alternative and effective method for high-energy tibial shaft fractures, including technical advantages of early trauma-control, the versatility of achieving excellent alignment, and the continuity of device until bone union.
机译:六脚踏地外固定器(HEF)越来越多地用于高能量胫骨轴断裂护理,因为更多一般的骨科外科医生正在获得这种多功能装置的专业知识。本研究的目的是评估HEF对高能量胫骨骨折患者的定期管理的临床效果。该研究是在34名患有胫骨骨折患者的患者进行,该胫骨骨折患者被录取或提交我们的机构,并同意从2016年1月至2019年6月的HEF治疗,其中27名男性和7名女性,平均年龄为39岁?年(范围为18至65岁) ?年)。患者的临床和放射数据,以及最终临床结果至少12?几个月的随访,并回顾性分析。根据Paley的分类,记录了所有并发症。使用该临床访问中的ilizarov标准(ASAMI)方法的研究和应用协会评估临床结果。所有患者均为26?周(范围为152个?周)并获得完整的骨头联盟。在所有患者中取得了令人满意的对准,所有患者都能够在最后一次临床访问中进行日常活动,毫无困难。并发症包括PIN道感染(44%),延迟联合(6%),壬尼(3%)和关节僵硬(3%)。 Asami Bony结果在31例患者中优异,良好3. asami功能效果在27名患者中优异,良好,6岁,并在1.使用六足外固定器的明确管理是一种替代和有效的高能量方法胫骨轴骨折,包括早期创伤控制的技术优势,实现优异的对准的多功能性,以及装置的连续性直至骨头联合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号