Influence of scaler tip design on root surface roughness, tooth substance loss and patients’ pain perception: an in vitro and a randomised clinical trial

机译:缩放器尖端设计对根表面粗糙度,牙物质损失和患者疼痛感知的影响:体外和随机临床试验

获取原文
           

摘要

The influence of scaler tip design on root surface roughness, tooth substance loss and patients’ pain perception is investigated. This article was divided into the following parts: Part 1 Surface roughness and substance loss: an in vitro study, which involves intact extracted teeth sectioned and treated using a piezoelectric ultrasonic device (PM200 EMS Piezon, Switzerland) with a conventional scaler tip (FS-407) and a Perio Slim (PS) scaler tip (Perio Slim DS-016A). All sectioned samples for tooth surface roughness (n?=?20) and tooth substance loss (n?=?46) analyses were measured and compared using a 3D surface texture analyser and scanning electron microscope (SEM) respectively, at baseline and following scaling. Part 2 Pain Perception: a clinical study, which was a split mouth study design including 30 participants with gingivitis and/or mild chronic periodontitis; treated with supra-gingival scaling from teeth #13 to #23. Subjects were randomised to group A or group B. Group A was treated first with PS scaler tips, whereas group B was treated first with conventional scaler tips. Pain perception was recorded using the visual analogue scale (VAS). In vitro study: both scaler tips caused significant reduction in root substance roughness after scaling (p 0.05) was observed. The PS scaler tip caused statistically significantly less root substance loss (p??0.05) when the initial thickness of the tooth was ?1000?μm. Clinical study: the participants reported significantly lesser pain score during scaling using the PS scaler tip (median: 3) than when using the conventional scaler tip (median: 5) (p??0.05). In the in vitro study, using a slim scaler tip design causes less tooth substance loss compared to a wider scaler tip design. In the clinical study, less pain was observed compared than a wide (conventional) scaler tip design.
机译:调查了缩放器尖端设计对根表面粗糙度,牙物质损失和患者疼痛感知的影响。本文分为以下部分:第1部分表面粗糙度和物质损失:体外研究,涉及完整的提取齿,使用压电超声装置(PM200 EMS压电,瑞士),具有传统的缩放器尖端(FS- 407)和Perio Slim(PS)缩放器提示(Perio Slim DS-016A)。针对牙齿表面粗糙度(n≤=α2)和牙物质损失(n≤=Δ46)分析,并使用3D表面纹理分析仪和扫描电子显微镜(SEM)分别在基线和后续缩放后进行测量。第2部分疼痛感知:临床研究,这是一个分裂的口腔研究设计,包括牙龈炎和/或轻度慢性牙周炎的30名参与者;从牙齿#13到#23的牙齿凝结缩放处理。受试者被随机化为A组或B组。A组首先用PS缩放尖端治疗,而B组首先用常规的缩放尖端治疗。使用视觉模拟量表(VAS)记录疼痛感知。体外研究:在观察到缩放(P 0.05)后,缩放器尖端都会导致根质粗糙度的显着降低。当牙齿的初始厚度是颗粒的初始厚度时,PS缩放器尖端导致统计学上显着较小的根部物质损失(p≤≤0.05)。临床研究:参与者在使用PS缩放器尖端(中位数:3)时,参与者报告的疼痛评分明显较小的疼痛评分比使用传统的缩放尖端(中位数:5)(p≤≤0.05)。在体外研究中,与更广泛的缩放尖端设计相比,使用纤薄的缩放器尖端设计导致牙齿物质损失较少。在临床研究中,观察到比广泛(常规)缩放器尖端设计比较的疼痛更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号