Accuracy of 3D Curvilinear Measurements on Digital Models Generated by Light Emitting Diode Scanned Impressions: A Cross-sectional Study

机译:发光二极管扫描印象产生的数字模型的3D曲线测量的准确性:横截面研究

获取原文
           

摘要

The advantages of digital models include customisation of appliances such as retainers, expanders, and indirect bracket setups for which measurements made along a curved line (curvilinear), would offer clinically more relevant information as opposed to linear measurements.Aim: The purpose of this study was to evaluate and compare the accuracy of 3 Dimensional (3D) curvilinear measurements on Digital models generated from Light Emitting Diode (LED) scanned impressions, with manual measurements on study models.Materials and Methods: The cross-sectional study consisted of maxillary arch rubber based impressions of eight patients selected on inclusion criteria of intact dentition having complete set of teeth with erupted second molar.These impressions were scanned with LED scanner (Medit Identica) and converted to Stereolithography (STL) files to generate 3D models.With the help of Ansys software curvilinear measurements were obtained from these models.These impressions were poured in dental stone to prepare study models and manual measurements were directly carried out on it with the help of brass wire and digital caliper.Measurements were made on different locations on the dental arch in various directions as the labial and palatal surface of central incisors and canine on left side along the long axis of the tooth from the cusp tip to the gingival margin and the buccal and palatal surface between the two interdental contact points of 2nd premolars.Unpaired t test was used to check the significant difference in means of different parameters.Results: No significant differences were found between central incisors labial surface (p=0.845) and palatal surface (p=0.722) and the canine measurements labial surface (p=0.721) and palatal surface (p=0.544) on digital models compared to study models, whereas significant difference was observed in premolar measurements (p-value≤0.05).Conclusion: STL files obtained by LED scanning the impressions did not exhibit significant deformation or loss of information while curvilinear measurements were evaluated, and higher accuracy was seen in the premolar measurement on palatal surface with digital models.
机译:数字模型的优点包括诸如沿着曲线(曲线)进行的测量的固定器,扩展器和间接支架设置的自定义,如曲线(曲线),将在临床上提供临床上的相关信息,而不是线性测量值。该研究的目的是评估和比较从发光二极管(LED)扫描的印象中产生的数字模型的3维(3D)曲线测量的准确性,有手动测量研究模型。材料和方法:横截面研究由上颌拱橡胶组成基于八名患者的印象,选择了完整牙列的完整牙列标准,其具有爆发的第二磨牙。用LED扫描仪(Medit Identica)扫描该印模并转换为立体刻录物(STL)文件以生成3D模型。在帮助下从这些型号获得ANSYS软件曲线测量。这些印象被吞噬为了准备学习模型和手动测量,借助黄铜线和数字卡钳直接进行了手动测量。在各种方向上的牙齿曲折上的不同地点上进行了数字卡钳。作为中央门牙和犬类的幽默曲线的不同位置进行了沿着牙齿长轴的左侧从尖端到牙龈边缘和颊和腭表面在2nd磨牙的两个齿间接触点之间。使用的T检验用于检查不同参数的手段的显着差异。结果:中央门牙唇表面(P = 0.845)和腭表面(P = 0.722)和犬测量的唇表面(P = 0.721)和腭表面(P = 0.544)之间没有显着差异(P = 0.721),与学习模型相比,数字模型上的腭表面(P = 0.544) ,而在婚前测量中观察到显着差异(p值≤0.05)。结论:通过LED扫描获得的STL文件展示展示不显着变形在评估曲线测量的同时,在评估曲线测量的同时,在腭表面的掠夺性测量中看到更高的准确度,数字模型在腭表面上看到了更高的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号