首页> 外文期刊>Journal of Ophthalmology >Comparing School-Aged Refraction Measurements Using the 2WIN-S Portable Refractor in Relation to Cycloplegic Retinoscopy: A Cross-Sectional Study
【24h】

Comparing School-Aged Refraction Measurements Using the 2WIN-S Portable Refractor in Relation to Cycloplegic Retinoscopy: A Cross-Sectional Study

机译:使用2WIN-S便携式折射器对狭窄视网膜检查视网膜镜检查的学龄折射测量进行比较:横截面研究

获取原文
获取外文期刊封面目录资料

摘要

Purpose . To assess the repeatability and agreement of refractive measurements using 2WIN-S photoscreening with the gold-standard cycloplegic retinoscope refraction. Design . Single centre, cross-sectional study. Methods . Spherical, cylindrical, axis, and spherical equivalent of 194 bilateral eyes of 97 children were assessed using a retinoscope and 2WIN-S. One week later, another operator repeated the 2WIN-S measurements. The primary outcome measures were to assess the repeatability and agreement between spherical equivalent, J0, and J45 readings of 2WIN-S. The repeatability of measurements was assessed by the within-subject standard deviation (2.77 Sw) and intraclass correlation coefficient (ICC). The agreement between devices was assessed using 95% limits of agreement. The extent of the agreement between cycloplegic retinoscopy and noncycloplegic 2WIN-S measurements was assessed using Bland–Altman analysis. Results . The mean age ± SD was 10.3?±?2.46 year (range, 4–14 years). The sphere, cylinder, and spherical equivalent measurements were found to be consistent with both apparatus ( r value 0.86). ICC for SE, J0, and J45 was 0.900, 0.666, and 0.639, respectively; Sw for SE, J0, and J45 was 0.61D, 0.30D, and 0.31D, respectively; Bland–Altman analysis of retinoscopy with cycloplegia and 2WIN-S for SE was 184/194 (95%) in 95% confidence interval, and the mean value was 0.46. J0 was 184/194 (95%), and the mean value is ?0.04. J45 was 181/194 (93%), and the mean value is ?0.15. Conclusion . The objective refractive measurement of 2WIN-S had good reliability and high agreement with the gold-standard retinoscopy refraction in children and adolescents. While consistency was observed, it is essential to take into consideration that it is a screening tool.
机译:目的 。通过使用2WIN-S光滑视觉镜折射来评估折射率的重复性和折射测量的一致性。设计 。单中心,横断面研究。方法 。使用视网膜镜和2win-s评估194个儿童双侧眼睛的球形,圆柱形,轴和球形等同物。一周后,另一个操作员重复了2Win-S测量。主要结果措施是评估球面等效项,J0和J45读数的可重复性和协议。通过内部标准偏差(2.77WS)和脑内相关系数(ICC)评估测量的可重复性。使用95%的协议限制评估设备之间的协议。利用Bland-Altman分析评估了束腹视网膜镜检查和非胞心病术和非胞杆菌术2win-S测量之间的协议程度。结果 。平均年龄±SD为10.3?±2.46年(范围,4-14岁)。发现球体,气缸和球形等效测量与两个装置(R值& 0.86)一致。 ICC对于SE,J0和J45分别为0.900,0.66,639; SE对于SE,J0和J45分别为0.61d,0.30d和0.31d;具有睫状镜和SE的细胞膜镜检查的平坦altman分析为95%置信区间的184/194(95%),平均值为0.46。 J0是184/194(95%),平均值是?0.04。 J45是181/194(93%),平均值是?0.15。结论 。 2WIN-S的客观折射测量与儿童和青少年的金标准视镜折射具有良好的可靠性和高协议。虽然观察到一致性,但必须考虑到它是一种筛选工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号