首页> 外文期刊>MATEC Web of Conferences >Analysis and optimization of rubidium spectrum lamp to eliminate frequency fluctuations of rubidium atomic frequency standard
【24h】

Analysis and optimization of rubidium spectrum lamp to eliminate frequency fluctuations of rubidium atomic frequency standard

机译:铷谱灯消除铷原子频率标准频率波动的分析与优化

获取原文
           

摘要

Rubidium atomic frequency standard (RAFS) is the most widely used frequency standard in space. The light used to pump the atoms and detect the resonance signal is emitted by rubidium spectrum lamp, so the light intensity of rubidium spectrum lamp directly determines the performance of RAFS. This paper discussed on-board RAFS’ output frequency fluctuations caused by rubidium spectrum lamp. The reason of frequency fluctuations from rubidium lamps was described. To obtain stable lamp light intensity, analysis and optimization of the lamp was developed. Relevant experiments were carried out to verify the optimization. The study content of this paper is beneficial to improve the performance of a single temperature controlled space RAFS physics package.
机译:铷原子频率标准(RAF)是空间中最广泛使用的频率标准。用于泵送原子并检测谐振信号的光被铷谱灯发射,因此铷谱灯的光强度直接确定RAF的性能。本文讨论了铷谱灯引起的车载RAF的输出频率波动。描述了铷灯的频率波动的原因。为了获得稳定的灯光强度,开发了灯的分析和优化。进行了相关实验以验证优化。本文的研究内容有利于提高单个温控空间RAF物理包的性能。