The paper analyzes the causes of disruptions in electricity delivery to critical users in power areas that operate distributed generation facilities (DG), hereinafter referred to as DG areas. Statistics is shown to be affected by the types of the excitation systems (ES) chosen for the DG generators, as well as by the relay protection (RP) settings as configured when designing the facilities. The paper dwells upon the specifications of the ES’s used in low-power generators, their effective applications, as well as the consequences of disturbances in the power area or in an external grid. It is proven herein that RP settings as configured by generator manufacturers are often suboptimal, which jeopardizes their further operation, prevents the operator from aligning these settings to those of the grid RPs, and results in unnecessary disconnections. The paper also details upon calculating the parameters of DG-enabled grids in the common software suits, as well as on how to make a list of effective contingencies. It further gives recommendations on grouping the calculation problems by initial disturbance to optimize the number of projected scenarios. The authors prove that ES selection and generator RP configurations must be appropriate if DG facilities are to deliver electricity reliably.
机译:本文分析了在经营分布生成设施(DG)的电力区域中的电力传递中断的原因,下文中称为DG区域。统计数据被认为受到DG发生器选择的激励系统类型的影响,以及在设计设施时配置的继电保护(RP)设置。该纸张停留在低发电机中使用的ES的规格,其有效应用,以及电力区域中干扰的后果或外部网格。这里经过验证的,通过发电机制造商配置的RP设置通常是次优,这危及其进一步的操作,防止运营商将这些设置对齐至网格RPS的那些,并导致不必要的断开连接。本文还详细介绍了Common软件套装中启用了DG的网格的参数,以及如何制定有效的突发事件列表。它还通过初始干扰进行了关于计算计算问题的建议,以优化投影场景的数量。如果DG设施可靠地递送电力,作者证明了ES选择和发电机RP配置必须是合适的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号