Evaluation of Dose Distribution and Normal Tissue Complication Probability of a Combined Dose of Cone-Beam Computed Tomography Imaging with Treatment in Prostate Intensity-Modulated Radiation Therapy

机译:锥形束计算机断层扫描成像组合剂量分布和正常组织并发症概率评价,治疗前列腺强度调制放射治疗

获取原文
           

摘要

Purpose: The purpose of this study is to evaluate the effects of cone-beam computed tomography (CBCT) on dose distribution and normal tissue complication probability (NTCP) by constructing a comprehensive dose evaluation system for prostate intensity-modulated radiation therapy (IMRT). Methods: A system that could combine CBCT and treatment doses with MATLAB was constructed. Twenty patients treated with prostate IMRT were studied. A mean dose of 78 Gy was prescribed to the prostate region, excluding the rectal volume from the target volume, with margins of 4 mm to the dorsal side of the prostate and 7 mm to the entire circumference. CBCT and treatment doses were combined, and the dose distribution and the NTCP of the rectum and bladder were evaluated. Results: The radiation dose delivered to 2% and 98% of the target volume increased by 0.90 and 0.74 Gy on average, respectively, in the half-fan mode and on average 0.76 and 0.72 Gy, respectively, in the full-fan mode. The homogeneity index remained constant. The percent volume of the rectum and bladder irradiated at each dose increased slightly, with a maximum increase of 1%. The rectal NTCP increased by approximately 0.07% from 0.46% to 0.53% with the addition of a CBCT dose, while the maximum NTCP in the bladder was approximately 0.02%. Conclusions: This study demonstrated a method to evaluate a combined dose of CBCT and a treatment dose using the constructed system. The combined dose distribution revealed increases of 1% volume in the rectal and bladder doses and approximately 0.07% in the rectal NTCP.
机译:目的:本研究的目的是通过构建前列腺强度调制的放射治疗(IMRT)的综合剂量评估系统来评估锥形束计算机断层扫描(CBCT)对剂量分布和正常组织并发症概率(NTCP)的影响。方法:构建了一种可以将CBCT和治疗剂量与MATLAB组合的系统。研究了用前列腺IMRT治疗的二十名患者。平均剂量为78 Gy的前列腺区域,排除从目标体积的直肠体积,前列腺的背侧为4mm的边缘,整个圆周7mm。组合CBCT和治疗剂量,评价剂量分布和直肠和膀胱的NTCP。结果:辐射剂量递送至2%,98%的目标体积平均分别在半风扇模式下平均增加0.90%和0.74Gy,分别在全风扇模式下平均0.76和0.72 Gy。均匀性指数保持不变。在每种剂量时照射的直肠和膀胱的体积略微增加,最大增加<1%。加入CBCT剂量,直肠NTCP增加约0.07%至0.53%,而膀胱中的最大NTCP约为0.02%。结论:本研究证明了一种评价CBCT组合剂量的方法和使用构造的系统的治疗剂量。组合剂量分布显示直肠和膀胱剂量中的<1%体积的增加,直肠NTCP中的约0.07%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号