In each cycle of the Heart on the Electrocardiogram there are generally P waves as a presentation of Atrial Muscle Depolarization, QRS waves as a presentation of Ventricular Muscle Depolarization and T waves as a presentation of Ventricular Muscle Repolarization. Some types of electrocardiographs only represent wave morphology and some other types of electrocardiographs are equipped with duration and amplitude information but are limited. This limitation of information is calculated manually using small boxes on ecg paper measuring 40 ms for duration and 1 mV for amplitude. The consequences of this manual calculation will require time and accuracy of the calculation results. This study aims to obtain the QRS wave duration along with the amplitude value in each cycle of cardiac examination results. Discrete data from the sampling results of the ECG continuous signal in the maximum filter amplitude to get peak R values. The position of integer peak R with the next peak R is the duration of the cycle. PQRST algorithm is used to obtain peak Q and peak S, so the duration of QS can be obtained by subtracting the position of integer peak S with integer position Q. 10 samples of discrete ecg Sinus Rhythm data from Physionet and 5 samples from ECG-UWG were used in this study. The results showed that all sample data in 3 cycles had a value of QRS duration and peak amplitude values ??Q, R and S. Peak amplitude R max values ??and R min physionet sample records were obtained in record 16273 which was 3,485 mV and record 16795 was 0.805 mV. The QRS duration for Bradicardia and Tachicardia is shown in record 16483 which is 40 ms and record 17052 which is 144 ms.
机译:在心电图上的心脏的每个循环中,通常存在P波作为心房肌肉去极化的呈现,QRS波作为心室肌肌去极化和T波作为心室肌肉再渗透的呈现。某些类型的心电图仅代表波形形态,另一些类型的心电图都配备了持续时间和幅度信息,但有限。这种信息限制是手动使用小盒子上的小盒子测量40 ms的持续时间和1 mV进行幅度。本手册计算的后果需要计算结果的时间和准确性。本研究旨在获得QRS波持续时间以及每循环检查结果的幅度值。来自最大滤波器幅度的ECG连续信号的采样结果离散数据以获得峰值R值。整数峰值R与下一个峰值R的位置是循环的持续时间。 PQRST算法用于获得峰值Q和峰值S,因此可以通过将整数峰值S与整数Q的位置q的位置来获得Qs的持续时间。10来自MeCG-UWG的离散ECG窦律数据的10个离散的ECG窦律数据。在这项研究中使用。结果表明,3个循环中的所有样品数据具有QRS持续时间和峰值幅度值的值Q,R和S.峰值幅度r max值Δθ和r min physioonet样品记录在记录16273中获得3,485 mv记录16795为0.805 mV。 Bradicardia和Tachicardia的QRS持续时间显示在记录16483中,为40毫秒和记录17052,为144毫秒。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号