首页> 外文期刊>Journal of the Brazilian Chemical Society >Determination of Elemental Impurities in Acyclovir Ointment and Raw Materials Using Microwave Acid Digestion (MW-AD) and ICP-MS
【24h】

Determination of Elemental Impurities in Acyclovir Ointment and Raw Materials Using Microwave Acid Digestion (MW-AD) and ICP-MS

机译:使用微波酸消化(MW-AD)和ICP-MS测定Acyclovir软膏和原料中的元素杂质

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Inorganic elements present in pharmaceutical products were determined by inductively coupled plasma-mass spectrometer (ICP-MS), employing microwave acid digestion as a sample preparation method. The most abundant isotopes, 75 As + , 65 Cu + , 52 Cr + , 58 Ni + , 208 Pb + , and 51 V + , were determined in acyclovir ointment and its constituents. Elemental impurities in the pharmaceutical samples were determined using an inductively coupled plasma-universal cell technology-mass spectrometer (ICP-UCT-MS) operated in kinetic energy discrimination (KED) and standard mode. The accuracy of the method was assessed by means of addition and recovery experiments. Except for Cr, spiked recoveries of the elements added to the samples before microwave acid digestion (MW-AD) step were between 95.1 and 126%, and after MW-AD step ranged from 85.6 to 132%. Limits of detection (LOD) obtained by proposed method is in agreement to those required by the U.S. Pharmacopeia Convention (USP), showing that the ICP-MS technique is well suited for quantification of these elements. The LOD's (ng L -1 ) for 51 V + , 52 Cr + , 58 Ni + , 65 Cu + , 75 As + and 208 Pb + in 1% v v -1 HNO 3 medium were: 2.2, 81.3, 91.9, 6.9, 0.2 and 3.1, respectively. The concentration of the analytes in these samples presented a wide range, varying from 2.3 ?± 0.8 ?μg kg -1 for As to 3446 ?± 47 ?μg kg -1 for Cr.
机译:通过电感耦合等离子体质谱仪(ICP-MS)测定药物产物中的无机元素,其采用微波酸消化作为样品制备方法。在Acyclovir软膏及其成分中,测定最丰富的同位素,75载+,65 Cu +,52cr +,58 Ni +,208pb +和51V +。药物样品中的元素杂质使用电感耦合的等离子体 - 万能电池技术 - 质谱仪(ICP-UCT-MS)以动能辨别(KED)和标准模式。通过添加和恢复实验评估该方法的准确性。除CR外,在微波酸消化(MW-AD)步骤之前,将添加到样品中的元素的尖刺回收率在95.1和126%之间,并且MW-AD步骤范围为85.6至132%。通过提出的方法获得的检测限制(LOD)与美国药典大约(USP)一致的人一致,表明ICP-MS技术非常适合定量这些元素。 1%VV-1 HNO 3培养基中的51 V +,52克拉+,58 Ni +,65 Cu +,75℃的LOD(Ng L -1)为:2.2,81.3,91.9,6.9分别为0.2和3.1。这些样品中的分析物的浓度呈现宽范围,从2.3?±0.8Ω·μg-1±0.8Ωμg-1的范围变化为3446Ω·±47ΩΩΩ00×1 kg -1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号