...
首页> 外文期刊>Journal of Pharmacy and Bioallied Sciences >Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study
【24h】

Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study

机译:在各种灌溉解决方案中确定工作长度的集成顶点定位器的效率:体内研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The objective of this in vivo study was to compare and evaluate the accuracy of VDW Gold (VDW, Munich, Germany) integrated apex locator (IAL) and Root ZX Mini (J. Morita Corp., Kyoto, Japan) in two different irrigating solutions.Materials and Methods:Forty patients who required extraction were included in the study. Following local anesthesia, access opening was performed under rubber dam isolation. Initial negotiation of canal was performed using size 10 K-Files (M-Access, Dentsply Maillefer, Ballaigues, Switzerland). Cervical preparation was carried out using Rotary ProTaper SX files (Dentsply Maillefer, Ballaigues, Switzerland) under copious irrigation with 3% sodium hypochlorite. Patients were divided into two groups of 20 each: Group I (NaOCl) and Group II (CHX). The working length (WL) was determined in triplicates for each tooth using Root ZX apex locator and with S1 ProTaper rotary file in continuous motion in case of VDW Gold IAL in the presence of 3% sodium hypochlorite and 2% chlorhexidine. Therapeutic extraction was performed and WL was determined using size 15 K-Files under 20× magnification.Results:The paired sample independent t test showed that there was no significant difference between the Root ZX and VDW apex locator in determining the minor foramen in NaOCl group (P = 0.234, 0.453 respectively) and CHX group (P = 0.085, 0.087) when compared with actual working length.Conclusion:Both the apex locators were equally effective in determining WL at 0.5 mm from the apex in presence of irrigating solutions, that is, NaOCl and chlorhexidine.
机译:体内研究的目的是在两种不同的灌溉解决方案中比较和评估VDW Gold(VDW,慕尼黑,德国)集成的Apex定位器(Ial)和根Zx Mini(J. Morita Corp.,京都,日本)的准确性。材料和方法:研究中包括提取的四十名患者。在局部麻醉之后,在橡皮坝隔离下进行进入开口。使用大小10 k文件进行运河的初始谈判(M-Access,Lentsply Maillefer,Ballaigues,Switzerland)进行。使用3%次氯酸钠的大量灌溉,使用旋转蛋白SX文件(Lentsply Maillefer,Ballaigues,Switzerland)进行宫颈准备。患者分为两组的20组:I族(NaOCl)和II组(CHX)。使用根ZX Apex定位器的每次牙齿的三份酸盐(WL)测定工作长度(WL),并且在存在3%次氯酸钠和2%氯己定的VDW金IIA的情况下,在连续运动中以S1蛋白旋转锉。进行治疗萃取,使用20×倍率下的尺寸15 k倍测定W1.结果:配对样品独立的T检验显示,根ZX和VDW顶点定位器在确定NaoCl组中的次要孔中没有显着差异(P = 0.234,0.453分别)和CHX组(P = 0.085,0.087)与实际工作长度相比。结论:顶点定位器在存在灌溉解决方案的情况下,Apex定位器两者同样有效地确定0.5mm的WL。是,NaoCl和氯己定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号