Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST

机译:眼压测量使用眼响应分析仪,动态轮廓Tonometer和Scheimpflug分析仪Corvis ST

获取原文
           

摘要

Purpose. To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST (CST) in healthy subjects. Methods. In a prospective, observational study, IOP measurements with GAT (GAT-IOPc), ORA (IOPcc), DCT (DCT-IOP), and CST (bIOP) were performed and analyzed in 94 healthy subjects. Results. Mean age of the participants was 45.6?±?17.2?years (range 18 to 81?years). Mean GAT-IOPc was 12.9?±?2.4?mmHg, mean DCT-IOP was 16.1?±?2.6?mmHg, and mean IOPcc was 15.6?±?3.3?mmHg. DCT-IOP and IOPcc were significantly higher than GAT-IOPc (P0.001). Mean bIOP was 13.5?±?2.4?mmHg that was slightly higher but not significantly different from GAT-IOPc (P=0.146). Correlation analysis of IOP values and central corneal thickness (CCT) revealed a negative correlation between GAT-IOPc and CCT (r?=??0.347; P=0.001). However, IOPcc, DCT-IOP, and bIOP showed no significant correlation to CCT. Only bIOP revealed a weak but significant age dependency (r?=?0.321, P=0.002). Conclusion. All tonometry devices showed a good agreement of biomechanical corrected IOP values with GAT-IOPc. As no influence of CCT on IOPcc, DCT-IOP, and bIOP was detectable, the used correction algorithms appear to be appropriate in these tonometers in the clinical setting. The highest agreement was found between GAT-IOPc and bIOP. However, bIOP weakly correlated with participants’ age. Further studies are needed to elucidate the role of bIOP for IOP measurement.
机译:目的。将具有Goldmann施置矫形器(GAT),眼响应分析仪(OOR),动态轮廓Tonometer(DCT)和Corvis ST(CST)与健康受试者的眼压(IOP)测量进行比较。方法。在预期的观察研究中,在94个健康受试者中进行并分析用GAT(GAT-IOPC),OOP测量,含有GAT(GAT-IOPC),OOP测量,OOP测量,并分析并分析。结果。参与者的平均年龄为45.6?±17.2?年(范围18至81岁)。平均gat-iopc为12.9?±2.4?mmhg,平均dct-iop是16.1?±2.6?mmhg,平均iopc为15.6?±3.3?mmhg。 DCT-IOP和IOPCC显着高于GAT-IOPC(P <0.001)。平均BIOP是13.5?±2.4?mmHg略高,但与GAT-IOPC有显着不同(P = 0.146)。 IOP值和中央角膜厚度(CCT)的相关分析显示GAT-IOPC和CCT之间的负相关(R?=→0.347; P = 0.001)。然而,IOPCC,DCT-IOP和BIOP显示与CCT没有显着相关性。只有BIOP揭示了弱但重要的年龄依赖性(R?= 0.321,P = 0.002)。结论。所有矫形器设备都表现出生物力学校正的IOP值与GAT-IOPC的良好协议。由于CCT对IOPCC,DCT-IOP和BIOP的影响是可检测到的,所用的校正算法似乎在这些台眼表中临床环境中的适当。 Gat-IOPC和BIOP之间发现了最高的协议。然而,BIOP与参与者年龄弱相关。需要进一步的研究来阐明BIOP对IOP测量的作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号