INTRODUCTION: With the advancement of bioelectrical impedance analysis method, body fat can be estimated with portable devices at home. These devices are popular in home body fat monitoring (HBFM). However, improper use of the device may provide erroneous result. AIM: This study aimed to find out the level of competency of the operator in HBFM. MATERIALS AND METHODS: A cross-sectional survey was conducted with 34 individuals (males = 11, females = 23) during March–December, 2017. A pretested questionnaire was used to collect information by expert interviewer. Data were collected about premeasurement precautions, steps followed in body fat measurement proper, and postmeasurement action. Survey data were expressed in mean, standard deviation, and percentage and statistically tested by unpaired t -test and Chi-square test according to necessity with α =0.05. Analyses were done in GraphPad Prism 6.01. RESULTS: Premeasurement precautions for maintaining proper hydration level were not followed by majority of the participants. Avoidance of exercise in preceding 12 h was not followed by 94.12% ( χ sup2/sup = 26.47, P 0.0001), voiding bladder before the measurement was not followed by 88.24% ( χ sup2/sup = 19.88, P 0.0001), and avoidance of diuretics (e.g., chocolate, caffeine) was not practiced by 82.35% ( χ sup2/sup = 14.24, P = 0.0002). Prescribed steps for measurement proper were followed by majority of the operators. However, 61.76% ( χ sup2/sup = 1.88, P = 0.17) forgot to keep log of the readings. CONCLUSION: Clinicians, fitness instructors, and nutritionists should emphasize on premeasurement factors for educating their clients for HBFM. This would help proper tracking of body fat level.
机译:简介:随着生物电阻抗分析方法的进步,可以在家中使用便携式设备估算体脂肪。这些器件在家庭体内脂肪监测(HBFM)中受欢迎。但是,设备不当使用可能提供错误的结果。目的:这项研究旨在找出惠贝费姆中运营商的能力水平。材料和方法:在2017年3月 - 12月期间,用34个个体(Males = 11,女性= 23)进行横截面调查。预先测试的调查问卷被专家面试官收集信息。收集数据关于最前感预防措施,步骤在体内脂肪测量中采取的措施,以及后释放作用。调查数据以平均值,标准偏差和百分比表示,并根据不配对的T -TEST和Chi-Square测试,根据需要α= 0.05。分析是在GraphPad Prism 6.01中进行的。结果:维持适当水合水平的前瞻性预防措施并未跟随大多数参与者。在12小时之前避免锻炼并不是94.12%(χ 2 = 26.47,p <0.0001),在测量之前,排尿膀胱在测量之前没有,在88.24%(χ 2 = 19.88,p <0.0001),并避免利尿剂(例如,巧克力,咖啡因)的实施方式82.35%(χ 2 = 14.24,p = 0.0002)。用于测量的规定步骤适当之后是大多数运营商。但是,61.76%(χ 2 = 1.88,p = 0.17)忘了保持读数的日志。结论:临床医生,健身教师和营养学家应强调对HBFM客户提供教育的前胸部因素。这将有助于正确跟踪体脂水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号